Install I/O Modules in a Fabric Interconnect
F1‐
15
Caution -
When installing the I/O Modules: - wear an ESD wrist strap - When the hardware is
out of its shipping package or the Fabric Interconnect chassis, make sure you place it in an ESD
safe bag or on a grounded work surface such as a rubberized work mat.
Using the I/O Module Lock
The I/O module lock operates in a 90-degree arc, and the slot in the handle indicates the
position of the module's lock.
Table 1, “I/O Module Lock Positions,” on page 70
shows the
positions for the locking I/O Modules. This locking mechanism is supported on all models of
Fabric Interconnect.
TABLE 1
I/O Module Lock Positions
Position
Slot on Handle
Comments
Closed/
Locked
For the Fabric Interconnect F1-15,
the locked position is horizontal (0
degree angle)
For the Fabric Interconnect F1-4, the
locked position is vertical (90 degree
angle)
When the module lock is closed, the module cannot be removed or inserted. In
this position, the module is held in place by a metal tab that contacts the Fabric
Interconnect's frame and prohibits moving the module around in its slot.
To unlock the module, use a screwdriver to turn the module handle 90 degrees
counter- clockwise until the handle is in the "open" position.
Open/
Unlocked
For the Fabric Interconnect F1-15,
the open position is vertical (90
degree angle)
For the Fabric Interconnect F1-4, the
open position is horizontal (0 degree
angle)
When the module lock is open, the module can be removed and inserted. In this
position, the module is held in its slot by only the module socket connecting to the
Fabric Interconnect's midplane.
This position is not supported for runtime operating of any I/O module. Modules
should be unlocked only temporarily, for example during a module swap, then
locked into place for runtime operation.
To lock the module in place by turning the knob 90 degrees clockwise until the
handle is in the "closed" position.
Install I/O Modules in a Fabric Interconnect
F1‐
15
To install I/O Modules in a Fabric Interconnect F1-15, you will need a #2 Phillips (cross-head)
screwdriver.
With the exception of the Management module, which must be installed in Slot 16 of the
chassis, the I/O modules may be installed in any of the remaining 15 slots. All I/O modules may
be installed or removed while the system is running. This procedure is supported by all models
of Fabric Interconnect F1-15.
Caution -
When tightening screws, make sure to tighten them to lightly snug. Do not
overtighten screws or they can break.
70
Oracle Fabric Interconnect Hardware User's Guide • July 2016
Summary of Contents for Fabric Interconnect F1-15
Page 1: ...Oracle Fabric Interconnect Hardware User s Guide Part No E50997 04 July 2016...
Page 2: ......
Page 8: ...Contents Index 173 8 Oracle Fabric Interconnect Hardware User s Guide July 2016...
Page 10: ...10 Oracle Fabric Interconnect Hardware User s Guide July 2016...
Page 94: ...94 Oracle Fabric Interconnect Hardware User s Guide July 2016...
Page 168: ...168 Oracle Fabric Interconnect Hardware User s Guide July 2016...
Page 172: ...172 Oracle Fabric Interconnect Hardware User s Guide July 2016...
Page 176: ...176 Oracle Fabric Interconnect Hardware User s Guide July 2016...