Testing the Installation
Note -
In order to tell the difference between a POST failure and a link up condition with no
activity, you must remove the SFP+ transceiver or copper cable. If the LED pattern persists, it is
a POST failure condition. If the yellow LED was indicating a link up with no activity condition,
it will turn off, which indicates a normal link down.
Table 7, “OK/Power LED States,” on page 26
lists the OK/Power LED states.
TABLE 7
OK/Power LED States
LED State
Meaning
Removal Status
Off
No power to the HBA
Removal is permitted, or the HBA must be configured
Flashing
Hot-plug in process
Removal is not permitted
Solid green
HBA is properly configured
Removal is not permitted
POST Results
Power-on self test (POST) is the default mode of self-test for the Sun Storage 16 Gb FC
ExpressModule HBA. No jumpers or connectors are necessary for this test to run. These tests
perform a quick confidence level check of the HBA before running the operational software.
At a minimum, the following tests are performed by POST:
■
Flash boot image checksum test
■
Internal ASIC RAM tests for proper ECC and parity operation
■
NL Port loopback test
Testing the Installation
This section contains the following topics:
■
“To Verify Proper Installation (Oracle Solaris)” on page 26
■
“To Configure the HBA (Oracle Solaris)” on page 27
■
“To Verify Attached Storage (Oracle Solaris)” on page 27
To Verify Proper Installation (Oracle Solaris)
Use the
cfgadm
command to verify proper HBA installation.
26
Sun Storage 16 Gb Fibre Channel ExpressModule Host Bus Adapter, Emulex Installation Guide For HBA Model
7101690 • January 2018