Setting the Hold Function
98
ZX2 User’s Manual
INTRODUCTION
MAIN
APPLICATIONS
& SETTING
METHODS
SPECIFI-
CATIONS
INDEX
SETTING
TRANSITION
CHARTS
DETAILED
SETTINGS
FLOW OF
OPERATION
CONTENTS
PREPARATION
FOR
MEASUREMENT
BASIC
SETUP
TROUBLE-
SHOOTING
Height
Double
Sheet
Detection
Positioning
Eccentricity
and Surface
Deflection
Steps
and
Warpage
Thickness
5
Return to RUN mode
• Generally, the held value continues to be output until the next measurement ends (the
sampling time elapses).
If you want to reset the held value before the next measurement ends, set the external input
to
(see page 118) and input a reset signal using the external input wire.
Press the
button to apply
the setting.
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Hold down the
button for
three seconds to switch to the
RUN mode.
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Hold down for
3 seconds
Out
Important
Analog output
Analog output
Maximum
value
Maximum
value
ON
ON
ON
Sampling period
Sampling period
When not using reset input:
When using reset input:
Maximum
value
Current
measured
value
Sampling period
Maximum
value
Current
measured
value
Sampling period
4 ms
or
more
4 ms
or
more
4 ms
or
more
Within
4 ms
Timing input
Timing input
OFF
OFF
OFF
Example: Hold condition = PEAK, trigger mode = TIMING, non-measurement output = CLAMP
Reset
execution
Clamp value
Reset input
*
* For the reset input timing, see the timing chart on page 144.