• If analog output is to be used, the entered thickness value is used as the center value of the
analog output range. (For example, 0 V is used if the analog output is ±5 V.)
• After thickness calculation, the maximum and minimum measurement range values (CH2
measurement values) are assigned as the maximum and minimum analog output range.
• Concerning the minimum and maximum analog output values, the analog output minimum
value is output for the smaller of the post-thickness calculation values, and the analog output
maximum value is output for the larger of these values.
Example:If the ZX2-LD50 is used, a thickness value of 20 mm is entered, and analog
output from –5 to 5 V is specified.
* The measurement range for the ZX2-LD50 is ±10 mm.
Measured Value After
Thickness Calculation
How the Measurement Value
Is Calculated
Analog
Output
10.000
Thickness value – (CH2 measurement range/2)
= 20.000
–
10.000
–5 V
20.000
Thickness value
= 20.000
0 V
30.000
Thickness value + (CH2 measurement range/2)
= 20.000
+
10.000
5 V