Smart tuning
*
To tune multiple workpieces or to tune workpieces having a different surface
condition:
page 80
5
Scaling
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
—
—
Check that the reference
workpiece is set in place.
Press the
button for one
second. When
/
is displayed, release
your finger from the button to
start execution of smart tuning.
If "
" flashes on the
sub-display for three
seconds, it indicates that
tuning was not possible.
Change the response time
setting to a larger value, and
try again.
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Press the button to display
.
Press the button to display
.
Press the
button to enable
setting of scaling.
Required
Smart tuning sets optimum sensing conditions
according to the operating conditions
(response time and color/state of workpiece)
Hold down for
1 second
Flashing
Pressing down
Pressed down
Optional
Set this item to change the display scale when you want to display
a digital value on the Amplifier Unit different from the actual
measured value. (e.g. to display the actual sensing distance)
Press to display
.
Default value: OFF
Press to display.