Smart tuning
(Use CH1 for these settings.)
*
To tune multiple workpieces or to tune workpieces having a different surface
condition:
page 80
Select the
desired value.
Press the button to select the
response time.
Select the response time to
match the size and moving
speed of the sensing object.
to
60 µs, 120 µs, 240 µs, 500 µs,
1 ms, 2 ms, 4 ms, 8 ms, 12 ms,
20 ms, 36 ms, 66 ms, 128 ms,
250 ms, 500 ms
Press the
button to apply
the setting.
* After the response time is
changed, the smart tuning
results are cleared, so be
sure to re-execute tuning.
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
—
—
Check that the reference
workpiece is set in place.
Press the
button
on the CH1
Amplifier Unit
for one second.
When /
is
displayed, release your finger
from the button to start
execution of smart tuning.
If "
" flashes on the
sub-display for three
seconds, it indicates that
tuning was not possible.
Change the response time
setting to a larger value, and
try again.
* After smart tuning
execution for CH1 ends, it is
also executed for the
Amplifier Units of CH2 and
later. If the tuning result is
NG for either Amplifier Unit,
the smart tuning setup
results are not applied to any
amplifier units.
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Press to select
Required
Smart tuning sets optimum sensing conditions
according to the operating conditions
(response time and color/state of workpiece)
Hold down for
1 second
Flashing
Pressing down
Pressed down