This section outlines the error messages displayed on the Amplifier Unit and the
countermeasures for those messages.
While displaying an error, the error output signal is also output. (There are some
exceptions.)
Display
Error
Countermeasure
Error-bright
Saturated light amount intensity,
measurement error.
(The error output signal is not output.)
• Install so that the distance between
the Sensor Head and the
workpiece is within the
measurement range.
Error-channel
• There is only one Amplifier Unit
even though mutual interference
prevention is set to ON.
• There is only one Amplifier Unit
even though two-Sensor operation
is set to ON.
• If two or more Amplifier Units have
been installed, turn OFF the power
supply and check that the Amplifier
Units and Calculating Units are
connected correctly.
• If only one Amplifier Unit is being
used, connect another Amplifier
Unit temporarily and turn OFF
mutual interference prevention and
two-Sensor operation, or initialize
the setting data.
Error-channel
Two Amplifier Unit communication
error.
Error-dark
Insufficient received light intensity,
measurement error.
(The error output signal is not output.)
• Install so that the distance between
the Sensor Head and the
workpiece is within the
measurement range.
Error-head
The Sensor Head is disconnected.
Or, a sensor communications error
has occurred.
• Turn OFF the power supply, check
the Sensor Head connection, and
then turn ON the power supply
again.
• If the above countermeasure does
not solve the problem, the Sensor
Head is malfunctioning. Replace
the Sensor Head.
Error-head
Error-head
Error-head
Sensor Head laser error.
Error-head
The Sensor Head internal memory is
in error.
Error-head