Mutual interference prevention setting
3
Return to RUN mode
• When CH1 is used to specify a setting while mutual interference prevention is set to ON, the
menus for which the same setting is applied to the Amplifier Units of CH2 and later are
shown in the following table.
Specify settings for the menus in the following table after setting mutual interference
prevention to ON.
• When connecting two or more Amplifier Units, the response times (maximum values) are as
follows:
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Press the button to display
.
Press the button to display
.
Press the
button to apply
the setting.
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Hold down the
button for
three seconds to switch to the
RUN mode.
Menu
Displayable and
Specifiable CH Number
Notes
Response time setting
CH1
The setting of CH1 is also applied to Amplifier Units of
CH2 and later.
Smart tuning
CH1
Smart tuning for the Amplifier Units of CH2 and later
are executed together with CH1.
Mutual Interference
Prevention
Two-Sensor
Operation
Total Response Time
OFF
OFF
Response time setting for each CH
(A – B), THICK
(Total response time setting for each CH) +
(4 ms × number of connected units)
ON
OFF
(Response time per unit in the table below) ×
number of connected units
(A – B), THICK
Press to display
.
Default value: OFF
Press to display.
Hold down for
3 seconds
Out
Important