Engineering Data (Reference Value)
151
ZX2 User’s Manual
INTRODUCTION
BASIC
SETUP
PREPARATION
FOR
MEASUREMENT
TROUBLE-
SHOOTING
INDEX
CONTENTS
SETTING
TRANSITION
CHARTS
FLOW OF
OPERATION
MAIN
APPLICATIONS
& SETTING
METHODS
DETAILED
SETTINGS
SPECIFI-
CATIONS
Height
Double
Sheet
Detection
Positioning
Eccentricity
and Surface
Deflection
Steps
and
Warpage
Thickness
Reference: Distance between two diffuse-
reflective models that causes malfunction
when mutual interference prevention is
turned off
The distance at which the resolution exceeded the rated value when sensors were moved
towards each other (in all the X, Y, and Z directions) while mutual interference prevention was
turned off was measured. (Workpiece: white ceramic; positioned facing the sensor, not on an
angle.)
Horizontal direction
Vertical direction
Results: For all models, the distance that causes malfunction is 0 mm in all the X,
Y, and Z directions.
Note. The above result was obtained when the white ceramic workpiece was positioned
facing the sensor, not on an angle.
Note that mutual interference can occur when using different types of workpieces or
when the sensors are attached at an angle, so it is recommended to use the
sensors with mutual interference prevention turned on.