Warming Up
After turning ON the power supply, allow the product to stand for at least 10 minutes
before use. The circuits are still unstable just after the power supply is turned ON, so
measured values may fluctuate gradually.
A warmup of at least 10 minutes is also required after canceling LD-OFF input if LD-
OFF input is being used.
Sensing Object
The product cannot accurately measure the following types of objects: Transparent
objects, objects with an extremely low reflective sensor ratio, objects smaller than the
beam size, objects with a large curvature, excessively inclined objects, etc.
Mutual Interference
Inserting a calculating unit between amplifier units can prevent mutual interference
between two sensor heads.
Maintenance
• Always turn OFF the power supply before adjusting or connecting/disconnecting
the sensor head.
• Do not use thinner, benzene, acetone or kerosene to clean the sensor head and
amplifier units. If large dust particles adhere to the front filter of the sensor head,
use a blower brush (used to clean camera lenses) to blow them off. Do not blow the
dust away with your mouth. To remove smaller dust particles, use a soft cloth (for
lenses) with a small amount of alcohol. Take care not to wipe them off with exces-
sive force.
Scratches on the filter may cause errors.