5-3
Section
Starting and Stopping Data Links
73
5-3-1 Using a Programming Device or a Ladder Program
Set the software switches (AR or DM Start Bit) in the PC to ON using a Program-
ming Device or from the ladder-diagram program.
Programming Device
User program
Startup node
Controller Link
CS1-series PCs
Turn ON the Start Bit in DM 3000 + 100
×
N.
(N: unit number)
C200HX/HG/HE PCs
Turn ON the Start Bit in AR 07
CV-series PCs
Turn ON the Start Bit in DM 2000 + 100
×
N.
(N: unit number)
+
The data links will start when the Start Bit changes from OFF to ON or is already
ON when power is turned ON. The data links will stop when the Start Bit changes
from ON to OFF.
Note
1. Refer to the Controller Link Units Operation Manual (W309) for details on
starting and stopping data links using a Programming Device or ladder pro-
gram.
2. The data in the AR and DM Areas is retained when power is turned off.
Therefore, by setting in the AR and DM Areas can be made in advance to
start data links as soon as power is turned on. It is recommended to set the
Start Bit to ON in multiple nodes that are participating in the data link so that
the data links will start even if the startup node is down. The same data link
settings must be set in these nodes for automatically set data links.
CS1-series Startup Node
Data link Start Bit
Start: Changed from OFF to ON or set to ON
when power is turned on
Stop: Changed from ON to OFF
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
Word N
N: DM 30000 + 100
×
(unit number)
C200HX/HG/HE Startup Node
Data link Start Bit for level 0 (AR 0700)
Start: Changed from OFF to ON or set to ON
when power is turned on
Stop: Changed from ON to OFF
Data link Start Bit of level 1 (AR 0704)
Start: Changed from OFF to ON or set to ON
when power is turned on
Stop: Changed from ON to OFF
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
AR 07