4-2
Section
Structure Descriptions
60
4-2-4 RINGBUFFER/*PRINGBUFFER Structure
This structure stores optical ring status that has been read. It is used by ClkGe-
tRingStatus().
Type
Variable name
Contents
WORD
wDisConnectionFlag
Disconnected Line Flags (See graphic following this table.)
WORD
wDisConnectionNodeInfo1
Disconnected node information 1 (See graphic following this
table.)
WORD
wDisConnectionNodeInfo2
Disconnected node information 2 (See graphic following this
table.)
BYTE
abyDisConnectionInfoRecordTime[6]
Starting time for disconnected information storage (See
graphic following this table.)
DWORD
dwNetworkSeparationCount
Number of network separations
DWORD
dwNewsorkDisConnectionCount
Number of network disconnections
DWORD
dwLocalNodeDisConnectionCount
Number of local node disconnections
DWORD
dwNetworkDisConnectionMaxCycleCount
Maximum number of cycles with continuous disconnection
DWORD
dwFrameDropOutsCountSL1
Number of frame dropouts for SL1
DWORD
dwFrameDropOutsCountSL2
Number of frame dropouts for SL2
DWORD
dwFrameBrakesCountSL1
Number of broken frames for SL1
DWORD
dwFrameBrakesCountSL2
Number of broken frames for SL2
DWORD
dwCrcErrorCountSL1
Number of CRC errors for SL1
DWORD
dwCrcErrorCountSL2
Number of CRC errors for SL2
Disconnected Line Flags
High Bits
Network Disconnected Flag
0: Normal
1: Disconnected
Low Bits
Local Node Disconnection Direction Flag
0: SL1 (upstream)
1: SL2 (downstream)
Local Node Disconnected Flag
0: Normal
1: Disconnected
(Valid when Local Node Dis-
connected Flag is ON.)
Disconnected Node Information
High Bits
Low Bits
Disconnection Direction Flag
0: SL1 (upstream)/Normal
1: SL2 (downstream)
Disconnected Node Address (2-digit hexadecimal)
Disconnected node information can be read out for up to two disconnections:
Disconnected Node Information 1 and Disconnected Node Information 2.