![Omron SYSMAC 3G8F7-CLK12-E Operation Manual Download Page 112](http://html1.mh-extra.com/html/omron/sysmac-3g8f7-clk12-e/sysmac-3g8f7-clk12-e_operation-manual_1633420112.webp)
6-4
Section
Response Codes
96
No. of records (command and response): Specifies the number of records to
be read, within a range of 0001 to 0027 in hexadecimal (decimal: 1 to 39).
Max. no. of stored records (response): Specifies the maximum number of re-
cords that can be recorded, within a range of 0001 to 0027 in hexadecimal (deci-
mal: 1 to 39).
No. of stored records (response): The number of records that have been re-
corded by the time the command is executed. For the Controller Link Support
Board this is fixed at 0027 Hex (decimal: 39.)
Error log data (response): The specified error log records are returned in se-
quence starting from the beginning record number. The total number of bytes
required is calculated as follows:
No. of records x 10 bytes
The configuration of each error record is as follows:
Details
Minutes
Seconds
Day Hour Year Month
Error code
1st byte
10th byte
Error code, details: These parameters show the contents of errors. For de-
tails, refer to 9-3-2 Error Codes.
Date and time: These parameters show the seconds, minutes, hour (0 to
23), date, month, and year (the rightmost two digits) in BCD specifying the
time that the error occurred.
Note If the PC does not have the specified number of records, all the records that have
been stored in the PC up to the point that the command is executed will be re-
turned.
6-3-15 ERROR LOG CLEAR
Clears all error log records and sets the error log pointer to 0.
Command Block
03
21
Command
format
Response Block
03
21
Command
format
Response
code
6-4
Response Codes
This section describes the response codes returned with responses to FINS
commands. Response codes can be used to confirm normal completion of com-
mand execution or to troubleshoot problems when commands fail. For further
troubleshooting information, refer to Section 9 Troubleshooting and Mainte-