![Omron SYSMAC 3G8F7-CLK12-E Operation Manual Download Page 85](http://html1.mh-extra.com/html/omron/sysmac-3g8f7-clk12-e/sysmac-3g8f7-clk12-e_operation-manual_1633420085.webp)
5-2
Section
Setting Data Links
69
4. In manual setting, a data link table must be set in the data link startup node
and in automatic setting, automatic data link setting parameters must be set
in the data link startup node. Data links will not be started unless the settings
are correct.
5-2-2 Manual Setting
Transfer the data link tables that were created on the Support Software to the
Controller Link Unit and the Controller Link Support Board at all node participat-
ing in the data links.
Transferring from a Programming Device
L
Nodes
Controller
Link Unit
CPU Unit
+
C200HX/HG/HE PCs
Nodes
Controller
Link Unit
CPU Unit
CV-series PCs
Transfer
Data link tables
Controller Link
Support Software
IBM PC/AT or
compatible
RS-232C
Nodes
Controller
Link Unit
CPU Unit
CS1-series PCs
Note
1. Data link tables cannot be set in the Controller Link Support Board using the
CX-Net in the CX-Programmer. Use the CLK Data Link Setting Utility in Fins-
Gateway or the Controller Link Support Software (version 2.00 or higher).
2. Refer to the Controller Link Support Software Operation Manual or the CX-
Net Operation Manual for actual setting procedures.
3. When transferring the data link tables to a Controller Link Unit for a CV-se-
ries PC, set the System Protect Keyswitch on the CPU Unit to “NORMAL.”
Otherwise, data link tables cannot be written normally.
Transferring from a Computer Node
Data link tables
IBM PC/AT or
compatible
Controller Link
Support Board
CLK Data Link
Setting Utility in
FinsGateway
Note To create data link tables for nodes in the network using the CLK Data Link Set-
ting Utility in the FinsGateway, the network must have been constructed correct-
ly. Set routing tables at each node as required. When using manually set data
links, be sure to delete data link tables for all nodes not participating in data link.
See 1-4 Applications Precautions for details. Refer to FinsGateway online help
for actual setting procedures for the CLK Data Link Setting Utility.