The Terminals of the NT-Series
Section 1-5
1.5.4
Pin Assignment X3 SER1 RS232c
Interface for communication with controller.
Pin
Designation
Channel
Function
1
Shield
SER1
Shield
6
TD
SER1
Transmit Data
15
CTS
SER1
Clear To Send
17
RTS
SER1
Request To Send
18
RD
SER1
Receive Data
25
SGND
SER1
Signal Ground
A shielded cable with stranding in layers (cable type LiYCY) and with a minimum
cross-section of 0.25 mm
2
must be used. The maximum cable length is 15 m.
Connect the cable shield to the metal hoods of the connectors over as large a
surface as possible!
1.5.5
Pin Assignment X3 SER2 RS232c
Interface for download, upload and logging printer.
Pin
Designation
Channel
Function
2
TD
SER2
Transmit Data
3
RD
SER2
Receive Data
4
RTS
SER2
Request to Send
5
CTS
SER2
Clear To Send
7
SGND
SER2
Signal Ground
20
DTR
SER2
Data Terminal Ready
A shielded cable with stranding in layers (cable type LiYCY) and with a minimum
cross-section of 0.25 mm
2
must be used. The maximum cable length is 15 m.
Connect the cable shield to the metal hoods of the connectors over as large a
surface as possible!
Summary of Contents for NT15S
Page 1: ...Cat No V056 E1 1 Programmable Terminal NT4S NT15S NT18S OPERATION MANUAL ...
Page 2: ...ii ...
Page 3: ...iii NT4S NT15S NT18S Programmable Terminal Operation Manual Produced March 1999 ...
Page 4: ...iv ...
Page 6: ...vi ...
Page 14: ...xiv ...
Page 26: ...12 The Terminals of the NT Series Section 1 2 1 2 4 1 2 NT4S SF122B E 1 2 4 1 3 NT4S SF123B E ...
Page 37: ...23 The Terminals of the NT Series Section 1 4 1 4 1 3 NT4S SF123B E 1 4 1 4 NT15S SF121B E ...
Page 54: ...40 The Terminals of the NT Series Section 1 7 1 7 6 3 ASCII Character Set Table ...
Page 58: ......
Page 60: ...46 ...
Page 70: ...56 ...
Page 200: ...186 ...
Page 212: ...198 ...
Page 214: ...200 ...