110
Standard Mode
Section 4-6
StartRestore
This variable controls the download from the PC to the Terminal.
Data type:
Numeric
Editor:
Selection text
Output:
---
Possible values:
(0)
Initial state
(1)
The terminal switches to the ready-to-receive
state
(2)
The terminal terminates a transmission currently
in progress.
RestoreState
This variable indicates the status of the transmission from the PC to the terminal.
Data type:
Numeric
Editor:
---
Output:
Selection text
Possible values:
(0)
Initial state
(1)
Data transmission in progress
RestoreLineNr
This variable indicates the current line number of the data set file. It is used to verify
the progress of the receive process and in the case of an error, for error localization.
Data type:
Numeric
Editor:
---
Output:
Numeric
Possible values:
1 to 255
StartRezPrint
This variable can be used to print data sets.
Data type:
Numeric
Editor:
Selection text
Output:
---
Possible values:
(0)
Initial state
(1)
Starts data set printout
(2)
Terminates print process
RezPrintState
When printing data sets, this variable indicates the current printing status.
Data type:
Numeric
Editor:
---
Output:
Selection text
Possible values:
(0)
Initial state
(1)
Data set printout in progress
Summary of Contents for NT15S
Page 1: ...Cat No V056 E1 1 Programmable Terminal NT4S NT15S NT18S OPERATION MANUAL ...
Page 2: ...ii ...
Page 3: ...iii NT4S NT15S NT18S Programmable Terminal Operation Manual Produced March 1999 ...
Page 4: ...iv ...
Page 6: ...vi ...
Page 14: ...xiv ...
Page 26: ...12 The Terminals of the NT Series Section 1 2 1 2 4 1 2 NT4S SF122B E 1 2 4 1 3 NT4S SF123B E ...
Page 37: ...23 The Terminals of the NT Series Section 1 4 1 4 1 3 NT4S SF123B E 1 4 1 4 NT15S SF121B E ...
Page 54: ...40 The Terminals of the NT Series Section 1 7 1 7 6 3 ASCII Character Set Table ...
Page 58: ......
Page 60: ...46 ...
Page 70: ...56 ...
Page 200: ...186 ...
Page 212: ...198 ...
Page 214: ...200 ...