79
Standard Slave Function
Section 4-6
4-6
Standard Slave Function
4-6-1
Standard I/O Communications as Standard Slave
An NE1A-series Controller can function as a Standard Slave. One NE1A-
series Controller can function simultaneously as a Safety Master, Safety
Slave, and Standard Slave.
The NE1A-series Controller’s internal status information is also included in
the data allocated to the Standard Master, and so a monitoring system using
a PLC can be established.
The following steps are required in order for an NE1A-series Controller to per-
form standard I/O communications as a Standard Slave.
1. Creation of I/O data (slave I/O) to use as a Standard Slave
2. Registration in the Standard Master
3. Connection settings in the Standard Master
Standard Slave Specifications
Note
(1) The maximum data size is eight input bytes or zero outputs bytes when a
Bitstrobe connection is selected.
(2) COS and cyclic connections cannot be used at the same time.
(3) When two Poll/COS or Poll/Cyclic connections are selected, the same
output destination is used, so the maximum output data size is 16 bytes.
For inputs, up to 32 bytes of data can be set for 2 connections.
4-6-2
Creating I/O Data (Slave I/O) to Use as Standard Slave
The I/O data to be used for the DeviceNet Slave must be created in order for
an NE1A-series Controller to perform standard I/O communications as a
Standard Slave. The memory blocks for this I/O data are called Slave I/O.
Standard I/O Connections
Number of connections
2 max.
Maximum data size
16 input bytes or 16 output bytes (per connection) (See note 1.)
Connection type
Poll, Bitstrobe, COS, or Cyclic
Standard PLC
Standard Master
NE1A
(Standard Slave)
Standard I/O communications
Slave IN
Slave OUT
IN Area
OUT Area
Summary of Contents for NE1A-SCPU01 - 07-2009
Page 3: ...iv...
Page 9: ...x TABLE OF CONTENTS...
Page 11: ...xii...
Page 15: ...xvi...
Page 70: ...35 Installation Section 3 1 Top Top Bottom Bottom...
Page 72: ...37 Installation Section 3 1 3 1 3 Dimensions and Weight Dimensions NE1A SCPU01 V1...
Page 85: ...50 Wiring Section 3 2...
Page 123: ...88 Explicit Message Communications Section 4 7...
Page 141: ...106 Safety Outputs Section 5 4...
Page 257: ...222 Connection Status Tables Section 10 8...
Page 261: ...226 NE1A series Controller Replacement Section 11 2...
Page 264: ...229 Appendix A Local Input and Test Output Setting Example Local Output Setting Example...
Page 266: ...231 Appendix A Programming Example Local Input and Test Output Setting Example...
Page 267: ...232 Appendix A Local Output Setting Example...
Page 269: ...234 Appendix A Programming Example Local Input and Test Output Setting Example...
Page 270: ...235 Appendix A Local Output Setting Example...
Page 273: ...238 Appendix A Local Input and Test Output Setting Example Local Output Setting Example...
Page 275: ...240 Appendix A Programming Example Local Input and Test Output Setting Example...
Page 276: ...241 Appendix A Local Output Setting Example...
Page 289: ...254...
Page 293: ...258 Index...