Analog Input Units
Each CP1W-AD041 Analog Input Unit provides four analog inputs.
•
The analog input signal ranges are 0 to 5 V, 1 to 5 V, 0 to 10 V, -10 to +10 V, 0 to 20 mA, and 4 to
20 mA. The resolution is 1/6,000. The open-circuit detection function is activated in the ranges of 1 to
5 V and 4 to 20 mA.
•
The Analog Input Unit uses four input words and two output words.
z
CP1W-AD041
(1)Analog Input Terminals
Connected to analog output devices.
•
Input Terminal Arrangement
Note
When using current inputs, voltage input terminals must be short-circuited with current input terminals.
(2)Expansion I/O Connecting Cable
Connected to the CPU Unit or Expansion Unit expansion connector. The cable is attached to the
Analog Input Unit and cannot be removed.
8-1-1
Overview
8-1-2
Part Names and Functions
V IN1
Voltage input 1
I IN1
Current input 1
COM1
Input common 1
V IN2
Voltage input 2
I IN2
Current input 2
COM2
Input common 2
V IN3
Voltage input 3
I IN3
Current input 3
COM3
Input common 3
V IN4
Voltage input 4
I IN4
Current input 4
COM4
Input common 4
CH
I IN1
I IN3
I IN2
VIN1
VIN2
VIN3
COM1
COM2
I IN4
VIN4
COM4
NC
AG
COM3
IN
(3) Expansion connector
(2) Expansion I/O
connecting cable
(1) Analog input terminals
CH
I IN1
I IN3
I IN2
VIN1
VIN2
VIN3
COM1
COM2
I IN4
VIN4
COM4
NC
AG
COM3
IN
I IN1
I IN3
I IN2
VIN1
VIN2
VIN3
COM1
COM2
I IN4
VIN4
COM4
NC
AG
COM3
Summary of Contents for CP1E-E10DT-A
Page 3: ......
Page 31: ...26 CP1E CPU Unit Hardware User s Manual W479...
Page 273: ...Index 4 CP1E CPU Unit Hardware User s Manual W479...
Page 275: ...Revision 2 CP1E CPU Unit Hardware User s Manual W479...
Page 276: ......