5 To perform shutdown processing of the devices when a power failure occurs
5-2 When using the included UPS monitoring software
BN50T/BN75T/BN100T/BN150T/BN220T/BN300T
5-4
5-2 When using the included UPS monitoring software
5-2-1 What is the PowerAct Pro
The included “PowerAct Pro” UPS monitoring software allows you to perform shutdown
processing of your PC when a power failure occurs.
It is possible to shut down multiple computers on the network.
You can perform desired operation by setting the automatic start/stop of the UPS
based on the schedule setting.
Note: Ensure that your PC completes shutdown within the backup time after a power failure
occurs. For the backup time, refer to “4-1-3 Backup Time Guidelines”.
For more information, refer to the manual in the CD-ROM.
5-2-2 What is the Simple Shutdown Software
The included “Simple Shutdown Software” allows you to automatically shut down the PC
when a power failure occurs.
For more information, refer to the manual in the CD-ROM.
5-2-3 How to connect
1
. Connect the UPS to a computer.
Cable: Included connection cable (RS-232C or USB)
Note: The RS-232C and USB cannot be used at the same time.
<RS-232C>
BN50T/BN75T
BN220T/BN300T
BN100T/BN150T
Connect to
RS-232C
terminal
Connector
Connector
Connect to
RS-232C
terminal
Connector
Connector
Connect to
RS-232C
terminal
Connector
Connect to RS-232C
connector on UPS
Connect to RS-232C
connector on UPS
Connector
Connect to RS-232C
connector on UPS
Included connection cable
(RS-232C)
Included connection cable
(RS-232C)
Included connection cable
(RS-232C)
Connect to RS-232C
port on PC
Connect to RS-232C
port on PC
Connect to RS-232C
connector on UPS
Connect to
RS-232C
connector
on UPS
Connect to
RS-232C
connector
on UPS
5 To perform shutdown processing of the devices when a power failure occurs
5-2 When using the included UPS monitoring software
BN50T/BN75T/BN100T/BN150T/BN220T/BN300T
5
5-5
<USB>
BN50T/BN75T
BN100T/BN150T
BN220T/BN300T
USB
Port
USB
Port
Connect to
USB terminal
Connect to
USB terminal
Connector
Connector
Connect to USB
port on PC
Connect to USB
port on PC
USB
Port
Connect to
USB terminal
Connector
Connect to USB
port on PC
Included connection cable (USB)
Included connection cable (USB)
Included connection cable (USB)
Connector
Connector
Connector
Connect to
USB Port on UPS
Connect to
USB Port on
UPS
Connect to
USB Port on
UPS
When connecting 2 or more computers to the UPS (Only when using PowerAct Pro)
Slave Agent
Master Agent
Slave Agent
PC PC PC
LAN
Power output
UPS
Connection cable
(RS-232C or USB)
Shutdown
Summary of Contents for BN100T
Page 2: ......
Page 24: ...1 Preparation BN50T BN75T BN100T BN150T BN220T BN300T 1 8...
Page 36: ...2 Installation and connection BN50T BN75T BN100T BN150T BN220T BN300T 2 12...
Page 54: ...3 Check and start operation BN50T BN75T BN100T BN150T BN220T BN300T 3 18...
Page 72: ...4 Maintenance and Inspection BN50T BN75T BN100T BN150T BN220T BN300T 4 18...
Page 88: ...6 Using the contact signal functions BN50T BN75T BN100T BN150T BN220T BN300T 6 8...
Page 94: ...8 Troubleshooting BN50T BN75T BN100T BN150T BN220T BN300T 8 4...
Page 96: ...9 Note of Chinese BN50T BN75T BN100T BN150T BN220T BN300T 9 2 2 FA OA 2 AC 50 60Hz AC AC...
Page 97: ...9 Note of Chinese BN50T BN75T BN100T BN150T BN220T BN300T 9 9 3 AC AC 3P 2P AC AC 5cm UPS UPS...
Page 99: ...9 Note of Chinese BN50T BN75T BN100T BN150T BN220T BN300T 9 9 5 1mA AC UPS AC UPS...
Page 109: ...Cut here...