![background image](http://html1.mh-extra.com/html/omega/sbr-ew100/sbr-ew100_user-manual_4033456061.webp)
4-20
IMSBR08-E2
4.5 Basic Setting Commands
p 4
Periodic printout mode
O F F
Disable periodic printout
I N S T
Print instantaneous values.
R E P O R T
Print the report data over the
interval.
Query
U R ?
Example
Carry out periodic printout every 2 hours with hour 0
as the reference. Print the measured values
(instantaneous values) at each interval.
U R M a n u a l , 0 0 , 2 h , I N S T
Description • When p1 is set to Auto, the periodic printout interval
synchronizes to the chart speed.
• If p4 is set to REPORT, set the type of report data on
each channel using the UM command.
UM
Sets the types of report
data that are output to the
periodic printout.
Syntax
U M p 1 , p 2 , p 3
<terminator>
p 1
Channel number
p 2
Type of report data
I N S T
Instantaneous value
A V E
Average value
M I N
Minimum value
M A X
Maximum value
S U M
Sum value
M I X
A m
maximum values
p 3
Sum scale
O F F
Integrates the data per scan interval.
/ s
Integrates the physical amount that
are in unit of /s.
/ m i n
Integrates the physical amount that
are in unit of /min.
/ h
Integrates the physical amount that
are in unit of /hour.
/ d a y
Integrates the physical amount that
are in unit of /day.
Query
U M [ p 1 ] ?
Example
Print the average values of channel 03 using periodic
printout.
U M 0 3 , A V E
Description • This setting is possible when printing of report data
(p4 is REPORT) is specified using the UR
command.
• About p3
The data for sum computation are sampled every
scan interval. For data with units such as /s, /min,
/h, and /day as in a flow rate, the data can be
summed over the unit time. Parameter p3 is valid
only for sum values.
• On models with the computation function (/M1
option), computation channels can be specified.
UB
Sets the display mode of
the bar graph.
Syntax
U B p 1 , p 2
<terminator>
p 1
Channel number
p 2
Bar graph display mode
N O R M A L
The reference position is set to
the smaller of the two values,
leftmost value and rightmost
value.
C E N T E R
The reference position is set to
the 50% position.
Query
U B [ p 1 ] ?
Example
Display channel 01 using a bar graph with the
reference position set to the 50% position.
U B 0 1 , C E N T E R
Description On models with the computation function (/M1 option),
computation channels can be specified.
UI
Sets whether to use moving
average (dot model).
Syntax
U I p 1
<terminator>
p 1
Use/Not use moving average (USE, NOT)
Query
U I ?
Example
Use moving average.
U I U S E
UJ
Sets whether to use the
input filter (pen model).
Syntax
U J p 1
<terminator>
p 1
Use/Not use the input filter (USE, NOT)
Query
U J ?
Example
Use the input filter.
U J U S E
UK
Sets whether to use of
partial expanded recording.
Syntax
U K p 1
<terminator>
p 1
Use/Not use partial expanded recording
(USE, NOT)
Query
U K ?
Example
Use partial expanded recording.
U K U S E
UL
Selects the display/record
language.
Syntax
U L p 1
<terminator>
p 1
Language (ENGLISH, JAPANESE)
Query
U L ?
Example
Use English.
U L E N G L I S H
XN
Selects the date format.
Syntax
U L p 1
<terminator>
p 1
Date format for displaying and printing
Y/M/D: (example) 2005/08/31
M/D/Y: (example) 08/31/2005
Summary of Contents for SBR-EW100
Page 1: ...IMSBR08 E2 SBR EW100 EW180 Recorder Communication Interface User s Manual...
Page 2: ......
Page 99: ...3 2002...