4-10
IMSBR08-E2
4.4 Setting Commands
4.4 Setting Commands
SR
Sets the input range.
When setting channels to skip
Syntax
S R p 1 , p 2
<terminator>
p 1
Channel number
p 2
Measurement mode (SKIP)
Query
S R [ p 1 ] ?
Example
Set channel 01 to skip.
S R 0 1 , S K I P
Description • This command cannot be specified while
computation is in progress.
• Measurements are not made on channels that are
set to SKIP.
When setting channels to voltage, TC, RTD,
or ON/OFF input
Syntax
S R p 1 , p 2 , p 3 , p 4 , p 5
<terminator>
p 1
Channel number
p 2
Measurement mode (Input type)
V O L T
DC voltage
T C
Thermocouple
R T D
Resistance temperature detector
D I
ON/OFF input
p 3
Range type
p 4
Leftmost value of span
p 5
Rightmost value of span
Query
S R [ p 1 ] ?
Example
Measure 0
⋅
C to 1760.0
⋅
C on channel 01 using
thermocouple type R.
S R 0 1 , T C , R , 0 , 1 7 6 0 0
Description • This command cannot be specified while
computation is in progress.
• Set p3 according to the table in section 4.3.
• For p4 and p5, enter an integer value of 5 digits or
less according to the table in section 4.3. The
decimal position is fixed to the position indicated in
the table in section 4.3.
When setting channels to 1-5V range
Syntax
S R
p 1 , p 2 , p 3 , p 4 , p 5 , p 6 , p 7 , p 8
<terminator>
p 1
Channel number
p 2
Measurement mode (Input type) (1-5V)
p 3
Leftmost value of span
p 4
Rightmost value of span
p 5
Leftmost value of scaling (
−
20000 to 30000)
p 6
Rightmost value of scaling (
−
20000 to 30000)
p 7
Scale decimal point position (0 to 4)
p 8
Whether to use 1-5V low-cut function (ON, OFF)
Query
S R [ p 1 ] ?
Example
Set channel 01 to 1-5V range and scale the input value
in the range 0.0 to 1200.0. Do not use the low-cut
function.
S R 0 1 , 1 -
5 V , 1 0 0 0 , 5 0 0 0 , 0 , 1 2 0 0 0 , 1 , O F F
Description • This command cannot be specified while
computation is in progress.
• For p3 and p4, enter an integer value of 5 digits or
less according to the table in section 4.3. The
decimal position is fixed to the position indicated in
the table in section 4.3.
• Be sure that p6 is greater than p5.
• Parameter p8 is valid only when the low-cut
function is enabled (see the UF command).
When computing the difference between
channels
Syntax
S R p 1 , p 2 , p 3 , p 4 , p 5
<terminator>
p 1
Channel number
p 2
Measurement mode (DELTA)
p 3
Reference channel
p 4
Leftmost value of span
p 5
Rightmost value of span
Query
S R [ p 1 ] ?
Example
Set channel 03 to channel difference computation with
respect to channel 01 (reference channel). Set the
leftmost and rightmost values of span to
−
200.0 and
200.0, respectively.
S R 0 3 , D E L T A , 0 1 ,
−
2 0 0 0 , 2 0 0 0
Description • This command cannot be specified while
computation is in progress.
• The reference channel must be a channel that is
smaller in channel number than itself.
• The range type is the same as that of the reference
channel.
• For p4 and p5, enter an integer value of 5 digits or
less according to the table in section 4.3. The
decimal position is fixed to the position indicated in
the table in section 4.3.
When setting the linear scaling
Syntax
S R
p 1 , p 2 , p 3 , p 4 , p 5 , p 6 , p 7 , p 8 , p 9
<terminator>
p 1
Channel number
p 2
Measurement mode (SCALE)
p 3
Input type
V O L T
DC voltage
T C
Thermocouple
R T D
Resistance temperature detector
D I
ON/OFF input
p 4
Range type
p 5
Leftmost value of span
p 6
Rightmost value of span
p 7
Leftmost value of scaling (
−
20000 to 30000)
p 8
Rightmost value of scaling (
−
20000 to 30000)
p 9
Scaling decimal point position (0 to 4)
Query
S R [ p 1 ] ?
Example
Scale channel 02 whose input range is 0 to 10 V to
−
100.0 to 500.0.
S R 0 2 , S C A L E , V O L T , 2 0 V , 0 , 1 0 0 0 ,
−
1 0 0 0 , 5 0 0 0 , 1