![background image](http://html1.mh-extra.com/html/omega/sbr-ew100/sbr-ew100_user-manual_4033456062.webp)
4-21
IMSBR08-E2
Commands
4
D/M/Y: (example) 31/08/2005
D.M.Y: (example) 31.08.2005
M.D.Y: (example) Aug.31.2005
Query
X N ?
Example
Set to the "2005/08/31" format.
X N Y / M / D
Description This setting applies to the format of the date shown on
the display and the date printed on the periodic printout,
manual printout, alarm printout, message printout,
recording start printout, and new chart speed printout.
Note
How this setting applies to the time printout format of the alarm
printout, message printout, recording start printout, and new chart
speed printout: The setting specifies the format of the "M/D" and
"Y/M/D" section when the time printout format is set to "M/D
H:M," "M/D H:M:S," or "Y/M/D H:M:S."
XT
Selects the temperature
unit.
Syntax
X T p 1
<terminator>
p 1
Temperature unit
C
°
C
F
°
F
Query
X T ?
Example
Use
°
F.
X T F
UF
Sets whether to use the
extended functions.
Syntax
U F p 1 , p 2 , p 3 , p 4
<terminator>
p 1
Bias function (USE, NOT)
p 2
Square root low-cut function (USE, NOT)
p 3
1-5V input low-cut function (USE, NOT)
p 4
Alarm delay function (USE, NOT)
Query
U F ?
Example
Use all the extended functions.
U F U S E , U S E , U S E , U S E
Description • The input offset is set using the VB command.
• The low-cut function is set using the SR command.
• The delay alarm is set using the SA and BD
commands.
UT
Selects the time printout
format.
Syntax
U T p 1 , p 2 , p 3 , p 4
<terminator>
p 1
Time printout format of the alarm printout
The available selections are the same as those
of p2. None is not available.
p 2
Time printout format of the message printout
H H : M M
Hour:Minute
H H : M M : S S
Hour:Minute:Second
M / D H : M
Month Day Hour:Minute
M / D H : M : S
Month Day Hour:Minute:
Second
Y M D H : M : S
Month Day Year Hour:Minute:
Second
N o n e
No time printout
p 3
Time printout format of the record start time
printout.
The available selections are the same as those
of p2. None is not available.
p 4
Time printout format of the new chart speed
printout.
The available selections are the same as those
of p2. None is not available.
Query
U T ?
Example
Set the all time printouts to Hour:Minute format.
U T H H : M M , H H : M M , H H : M M , H H : M M
XR
Sets the remote control input
(/R1 option).
Syntax
X R p 1 , p 2
<terminator>
p 1
Remote control input terminal number (1 to 5)
p 2
Action
N O N E
No action
R e c o r d O n / O f f
Start/Stop recording.
C h a r t s p e e d
Change the chart
speed.
T i m e a d j u s t
Reset the internal clock
to the nearest hour.
M a t h s t a r t / s t o p
Start/Stop
computation.
M a t h r e s e t
Reset computation.
M a n u a l p r i n t
Execute manual print.
A l a r m A c k
Execute alarm
acknowledge.
M e s s a g e 1
Print message 1
M e s s a g e 2
Print message 2
M e s s a g e 3
Print message 3
M e s s a g e 4
Print message 4
M e s s a g e 5
Print message 5
Query
X R [ p 1 ] ?
Example
Assign the printout of message 2 to the remote control
input of terminal number 1.
X R 1 , M e s s a g e 2
Description Math start/stop and Math reset can be specified on
models with the computation function (/M1 option).
YS
Sets the RS-422A/485 interface
(/C3 option).
Syntax
Y S p 1 , p 2 , p 3 , p 4 , p 5
<terminator>
p 1
Address (1 to 32)
p 2
Baud rate (1200, 2400, 4800, 9600, 19200,
38400)
p 3
Data length (7, 8)
p 4
Parity check (ODD, EVEN, NONE)
p 5
Protocol (NORMAL, MODBUS)
Query
Y S ?
4.5 Basic Setting Commands