Page 5-4
Chapter 5 Programming
5.4.3.1 Unit tag
The Unit tag is the default display that shows in the Status Line at the top of the display. It may be used
to identify a place or process being monitored by the Recorder. The Unit tag can be any number or alpha
character string of up to 20 characters.
To select Unit tag as the Powerup display:
Use the
UP (
↑↑↑↑↑
)
or
DOWN (
↓↓↓↓↓
)
button to highlight
Unit tag
and then press the
ENTER
button. You will be
provided with an alphanumeric keypad. Use the
LEFT (
←
←
←
←
←
)
or
RIGHT (
Æ
Æ
Æ
Æ
Æ
)
button to move the cursor to the
edit position and then use the alphanumeric keypad to enter the Unit tag you wish to display. The
PAGE
button selects the next page of characters, the
PAGBK
button returns to the previous page of characters,
the
SHIFT
button toggles between upper and lower case letters, and the
SPC
button enters a space.
When you are done, press the
ENTER
button and then the
EXIT
button to return to the Display menu. You
can press the
EXIT
button to cancel at any time without changing the current setting.
5.4.3.2 Auto jog
The Auto jog Powerup display jogs (or scrolls) through each programmed point with the point status and
value at the programmed Display rate. The programmed Display rate can be 1 to 60 second intervals,
programmed under PROGram, Displays, Display rate (see Section 5.4.1).
To select Auto jog as the Powerup display:
Use the
UP (
↑↑↑↑↑
)
or
DOWN (
↓↓↓↓↓
)
button to highlight
Auto jog
and then press the
ENTER
button. Press the
EXIT
button to return to the Display menu.
5.4.3.3 Point
The Point Powerup display allows a programmed point to be displayed as the default Status Window value
or the unit prompt. The point number programmed, the current value of that point, and the engineering
units will be displayed as the unit Powerup prompt in the Status Line.
To program a programmed point to act as the Powerup display:
Use the
UP (
↑↑↑↑↑
)
or
DOWN (
↓↓↓↓↓
)
button to highlight
Point
and then press the
ENTER
button. You will be
provided with a keypad to select the point you wish to use, 1-9 or A-F. Select the point you want and press
the
ENTER
button or press the
EXIT
button to return without changing the point. Press the
EXIT
button
again to return to the Display menu.
5.4.3.4 Alarms
The Alarms Powerup display will jog (or scroll) through all points in Alarm at the programmed Display rate.
If all points are in Alarm, each point will be displayed at the Display rate in the Status Line. If no points are
in Alarm, the unit Powerup display will show “NO ALARMS”.
To select Alarms as the Powerup display:
Use the
UP (
↑↑↑↑↑
)
or
DOWN (
↓↓↓↓↓
)
button to highlight
Alarms
and then press the
ENTER
button. Press the
EXIT
button to return to the Display menu.
5.4.3.5 Junction Temp
The Junction Temp Powerup display will display the temperature in Degrees F [
°
F] (Degrees C [
°
C] with
European Time format selected) of the cold junction reference compensator in the Status Line.
To select Junction Temp as the Powerup display:
Use the
UP (
↑↑↑↑↑
)
or
DOWN (
↓↓↓↓↓
)
button to highlight
Junction Temp
and then press the
ENTER
button. Press
the
EXIT
button to return to the Display menu.