Chapter 3 Getting Started
Page 3-11
3.6.2 Input Scale
To set the
Input scale
:
1. From the
Point Setup
menu use the
UP (
↑↑↑↑↑
)
or
DOWN (
↓↓↓↓↓
)
button to highlight
Input scale
and then press
the
ENTER
button.
2. You will be presented with a character keypad and asked for the value to represent the
lo
w or bottom end
of the input scale and for this range; it will default to 0.0000. Up to thirteen characters can be entered. For
our programming example, press the
ENTER
button to accept
0.0000
as the low end value.
3. You will then be asked for the value to represent the
hi
gh end of the input scale. This value will default to
1.2500. For the sake of this exercise, use the character buttons to enter
1.0
and then press the
ENTER
button which will return you back to the
Point Setup
menu.
3.6.3 Output Scale
The Output scale is the value that will be reflected on the display or recorded to the units and will once again be
scaled by using the Chart scale programmed at a later time.
To set the
Output scale
:
1. From the
Point Setup
menu use the
UP (
↑↑↑↑↑
)
or
DOWN (
↓↓↓↓↓
)
button to highlight
Output scale
and the press
the
ENTER
button.
2. You will be asked to specify the number of decimal
places?
(0-5). For this example, use the
UP (
↑↑↑↑↑
)
or
DOWN (
↓↓↓↓↓
)
button to select
3
decimal places and then press the
ENTER
button.
3. You will be presented with the value for the
lo
w end of the output scale which defaults to 0. Press the
ENTER
button to accept
0
.
4. You will be presented with the
hi
gh value which defaults to 1. Use the character buttons to enter
100.0
and
then press the
ENTER
button which will return you back to the
Point Setup
menu.
You have now effectively programmed the Output scale to represent 100 times the Input scale.
3.6.4 Engineering Units
To set the
Eng
ineering
Units
:
1. From the
Point Setup
menu use the
UP (
↑↑↑↑↑
)
or
DOWN (
↓↓↓↓↓
)
button to highlight
Eng Units
and then press the
ENTER
button.
2. You may enter up to five characters representing the
Eng
ineering
units
using the alphanumeric keypad in
the page mode as done for the
Point tag
. For this example, press the
PAGE
button until you see the
percent sign (
%
) button.
3. Press the
%
button and then press the
ENTER
button which will return you back to the
Point Setup
menu.
You have now programmed the
Eng
ineering
units
to percent (%).
3.6.5 Chart Scale
To finalize the display scaling, we need to set the
Chart scale
. The actual Chart scale values are programmed
elsewhere and are covered in section 3.7.
To set the
Chart scale
:
1. From the
Point Setup
menu use the
UP (
↑↑↑↑↑
)
or
DOWN (
↓↓↓↓↓
)
button to highlight
Chart scale
and then press
the
ENTER
button.
2. You must choose one of eight scales (A-H). The default is
chart scl= A
. For the sake of this example, use
the
UP (
↑↑↑↑↑
)
or
DOWN (
↓↓↓↓↓
)
button to specify
chart scl=
B
and then press the
ENTER
button which will return
you back to the
Point Setup
menu.
You have now successfully programmed a point. To save your programming, press the
EXIT
button. You will be
asked if you want to
keep setup?
. Press the
ENTER
or
YES
button to save your programming. Then press the
EXIT
button twice to return to the default display.