45584901TH Rev.1
4-21 /
Oki Data CONFIDENTIAL
4.3.19
Auto Trapping width/density adjustment (PS)
<Adjustment Mode (05)>
Code
Item to be adjusted
Remarks
8244-0 Trapping width (dot)
Sets the value of width for auto trapping. When the value
increases, the bigger gap is suppressed, but the overlap
part becomes more visible.
1: 1 dot
2: 2 dot
3: 3 dot (default)
8214
Trapping density (%)
Sets the value of density for auto trapping. When the value
increases, the bigger gap is suppressed, but the overlap
part becomes more visible.
0: 100% (default)
1: 75%
2: 50%
3: 25%
<Procedure>
The procedure is the same as that of
P. 4-13 “4.3.4 Adjustment of faint text”.