45584901TH Rev.1
11-122 /
Oki Data CONFIDENTIAL
05/08 Mode Element
Sub
element
Item
Subitem
Code Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce-
dure
08 Setting
mode
System MFP
function
setting
8914
17
Network
InternetFAX
1
0-1
SYS Sets whether the Network InternetFAX function is
enabled or disabled.
0: Disabled
1: Enabled
4
08 Setting
Mode
System Network
8915
Automatic output of
jobs at login
1
0-1
SYS Sets whether jobs registered in the hold queue of user
are automatically output or not when the user logs in.
0: Disabled
1: Enabled
1
08 Setting
Mode
System Security
8919
Service password
-
-
SYS
Sets the password to log into the self-diagnostic mode
and Service UI.
11
08 Setting
Mode
System Option
FAX
8920
Output bin for FAX/
InternetFAX/e- mail
printing
0
0-2
SYS
Selects the bin/tray onto which the received document
exits.
w/o Finisher
0: Face down stacker
1: Face down stacker
2: Face down stacker
w/ Finisher
0: Face down stacker
1: Finisher
2: Finisher
1
08 Setting
mode
System Depart-
ment
manage-
ment
8921
Clearing of the user/
department counter
1
0-1
SYS
0: Not allowed
1: Allowed
1
08 Setting
mode
System User
interface
8922
Email header print
setting
0
0-1
SYS
Sets whether the header of an Email or an Internet Fax
is printed or not as they are received.
0: Not printed
1: Printed
1
08 Setting
mode
System User
interface
8923
Email body print
setting
1
0-1
SYS
Sets whether the body of an Email or an Internet Fax is
printed or not as they are received.
0: Not printed
1: Printed
1
08 Setting
mode
System User
interface
8924
Registration of the
received FAX /
Internet Fax / Email
jobs to hold queue
0
0-1
SYS
Registers the received Fax / Internet Fax / Email jobs
to the hold queue instead of printing immediately. Data in
the hold queue are not printed unless the user
allows printing by means of the control panel.
0: Not registered (normal printing)
1: Registered
1
08 Setting
mode
System
8925
Data tampering
checking at start-up
0
0-1
SYS
Sets whether data tampering is checked or not at startup.
0: Not checked
1: Checked
* When the value of 08-8911 is set to "3" (Security mode:
High level), the value of this code is automatically set to
"1."
1