05/08 Mode Element
Sub
element
Item
Subitem
Code Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce-
dure
08 Setting
mode
System General
9012
Language selection
to be displayed at
power-ON
English
-
SYS en_US: English de_DE: German fr_FR: French
es_ES: Spanish it_IT: Italian ja_JP: Japanese
en_GB: English (British) zh_CN: Simplified Chinese
zh_TW: Traditional Chinese ko_KR: Korean
<Default value>
ODA: English
Others: English (British)
11
08 Setting
mode
System User
interface
9016
Externally installed
counter
0
0-3, 5
SYS
0: No external counter
1: Coin controller (If the value of 08-9979 is "0" (ACS), it
is changed to "2" (Full color).)
2: Copy key card (This value is valid only when "2" is set
for 08-9000.)
3: Key copy counter
5: Coin controller supporting ACS/mixed-size (The value
of 08-4131 is set to "1")
* This code is a special code which has areas in both
SYS-SRAM and PU. The default value in SYS-SRAM is
applied to the PU area at initialization.
1
08 Setting
mode
System Counter
9017
Setting for counter
installed externally
1
0, 1, 4, 5 SYS
Selects the job to count up for the external counter.
0: Not selected
1: Copier
4: Printer
5: Copier/Printer
* This code is a special code which has areas in both
SYS-SRAM and PU. The default value in SYS-SRAM is
applied to the PU area at initialization.
1
08 Setting
Mode
System General
Memory
9020
Size information of
memory
-
-
SYS
Displays the sizes of the main memory and page
memory.
Enables to check if each memory is properly
2
08 Setting
Mode
System Initializa-
tion
9030
Initialization after
software version up
-
-
SYS Perform this code when the software in this equipment
has been upgraded.
3
08 Setting
Mode
System User
interface
Counter installed
externally
9037
Job handling-short
paid-coin controller
1
0-1
SYS
Sets whether pause or stop the printing job when it is
short paid using a coin controller.
0: Pause the job
1: Stop the job
1
08 Setting
Mode
System Mainte-
nance
General
9050
Performing panel
calibration
-
-
SYS
Performs the calibration of the pressing position on the
touch panel (LCD screen).
The calibration is performed by pressing 4 reference
positions after this code is started up.
1
08 Setting
Mode
System User
interface
Display setting
9051
Panel calibration
setting value
0
0-1
SYS
Switches whether the screen for displaying panel
calibration setting values is displayed or not.
0: Disabled (screen not displayed)
1: Enabled (screen displayed)
1