4.3.12
Toner limit threshold adjustment
<Adjustment Mode (05)>
Smooth/
Auto (PS/
PCL/ XPS)
Detail (PS/
PCL/ XPS)
Smooth/
Auto
(1200dpi)
Detail
(1200dpi)
Paper type
Remarks
8071-0
8070-0
8090-0
8089-0 Plain paper
When you set a larger value, the
density becomes high in some
parts of the high density area
since the maximum amount of
toner adhering increases.
When you set a smaller value,
the reproduction of the gradation
tends to be reduced since the
maximum amount of toner
adhering decreases and the
maximum density becomes low.
Be aware that if too large a
value is set, offsetting occurs.
Acceptable values: 0 to 255
(Default: 128)
8071-2
8070-2
8090-2
8089-2 Thick paper 5
8071-3
8070-3
8090-3
8089-3 Thick paper 1
8071-4
8070-4
8090-4
8089-4 Thick paper 2
8071-5
8070-5
8090-5
8089-5 Thick paper 3
8071-6
8070-6
8090-6
8089-6 Thick paper 4
8071-7
8070-7
8090-7
8089-7 Special paper
1, 2
8071-8
8070-8
8090-8
8089-8 Special paper
4 to 6
8071-9
8070-9
8090-9
8089-9 User type
8071-10
8070-10
8090-10 8089-10 Plain (Thin)
8071-11
8070-11
8090-11 8089-11 Envelope
8071-12
8070-12
8090-12 8089-12 Special paper
3
<Procedure>
The procedure is the same as that of
P. 4-9 “4.3.2 Gamma balance adjustment (Black Mode)”.