45584901TH Rev.1
11-171 /
Oki Data CONFIDENTIAL
05/08 Mode Element
Sub
element
Item
Subitem
Code Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce-
dure
08 Setting
mode
System
Wireless
LAN
9649
Wireless LAN
setting
2
1-2
NIC
Sets whether the wireless LAN connection is enabled or
disabled.
1: Enabled
2: Disabled
12
08 Setting
mode
System Network
DHCP
9694
Enabling server's IP
address acquired by
DHCP
1
1-2
-
DNS domain name Option (15) DNS domain name of the
client
1: Enabled
2: Disabled
This value is used only when DHCP is enabled.
12
08 Setting
mode
System User
interface
9698
Color mode
notification setting
at ACS
0
0-1
SYS
0: Color
1: Black
1
08 Setting
Mode
System Mainte-
nance
General
9700
Service technician
telephone number
0
32 digits
SYS
A telephone number can be entered up to 32 digits. Use
the [MONITOR/PAUSE] button to enter a hyphen(-).
11
08 Setting
mode
System User
interface
9702
Automatic
calibration
disclosure level
1
0-2
SYS
Sets the disclosing level of automatic calibration.
0: Service technician
1: Administrator
2: User
1
08 Setting
Mode
System Mainte-
nance
General
9703
Error history display
-
-
SYS
Displays the latest 20 errors data
2
08 Setting
mode
System Network
Scanning
9709
Default data saving
directory of "Scan to
File"
0
0-2
SYS 0: Local directory
1: REMOTE 1
2: REMOTE 2
1
08 Setting
Mode
System Mainte-
nance
RDMS
General
9710
Remote-controlled
service function
2
0-2
SYS 0: Valid (Remote-controlled server)
1: Valid (L2)
2: Invalid
1
08 Setting
Mode
System Mainte-
nance
RDMS
HTTP
9711
Remote-controlled
service URL setting
-
-
SYS
Maximum 256 letters
11
08 Setting
Mode
System Mainte-
nance
RDMS
HTTP
9715
Initially-registered
server URL setting
Refer
to
contents
-
SYS
Maximum 256 letters
<Default value>
https://device.mfp- support.com:443/device/firstregist.
ashx
11
08 Setting
mode
System Mainte-
nance
(Remote)
RDMS
9718
Short time interval
setting of recovery
from Emergency
Mode
24
1-48
SYS
Sets the time interval to recover from the Emergency
Mode to the Normal Mode.
(Unit: Hour)
1
08 Setting
mode
System Mainte-
nance
RDMS
9719
Short time
interval setting of
Emergency Mode
60
30-360
SYS
Unit: Minute
1
08 Setting
Mode
System Mainte-
nance
RDMS
General
9723
Periodical polling
timing
1430
0-2359
SYS
(Hour/Hour/Minute/Minute)
0 (0:00) to 2359 (23:59)
1