▌Restore the data saved for calibration backup.
▌If calibration done without knowledge or by user's mistake, you can retore previous data.
CAL_RESTORE
▌Power on while pressing DYN SETTING,FACTORY key.
▌Power on
▌Release the key after model name is displayed and entered
"--- FACTORY ---" mode.
▌Move to CAL_RESTORE menu.
"2.CAL_RESTORE" will be displayed.
FACTORY menu order: 1.USER_CLEAR ↔ 2.CAL_RESTORE ↔ 3.CAL_BACKUP ↔
4.CAL_DEFAULT ↔ 5.LOAD_DEFAULT ↔ 6.DELIMITER_CHAR ↔
7.COM_RESPONSE ↔ 8.AUTO_KEY_LOCK ↔ 9.ADC_SAMPLING
▌Press DYN SETTING,FACTORY key.
After "CAL.RESTORE_DONE" is displayed, saved Calibration data will be
loaded.
▌Power OFF
5-4. CAL_RESTORE
Press and hold
- 74 -
Release
DYN SETTING
FACTORY
POWER
DYN SETTING
FACTORY
DYN SETTING
FACTORY
POWER