To set the RANG in Constant Current and Constant Voltage, proceed as follows.
CC,CV RANG SET
▌Power On
▌When INPUT is OFF
▌Enter CC/CV RANG menu
Press CC/CV RANG KEY.
▌CC/CV RANG setting
Move to CC/CV RANG menu by using left/right key
※CC/CV RANG menu order:
1:CC.H_CV.H ↔ 2:CC.L_CV.H ↔ 3:CC.H_CV.L ↔ 4:CC.L_CV.L
▌Saving CC/CV RANG
Press CC/CV RANG KEY.
After saving CC/CV RANG,
exit CC/CV RANG menu and return to manual mode.
Note
CC/CV RANG KEY is only available when INPUT of CC/CV mode is OFF
Setting of CC/CV RANG is only available in CC/CV mode
on the other hand, it always operate as HI RANG state
※When change the VOLT RANG, Please eliminate the Source.
(OVER RANG or OVER VOLT can be occure when change RANG because of Instantaneous voltage)
3-10.CC,CV RANG
- 46 -