ADC Data Register 1 (ADC_DAT1)
Register
Offset
R/W
Description
Reset Value
ADC_DAT1
0x04
R
ADC Data Register 1
0x0000_0000
31
30
29
28
27
26
25
24
ADC1VALID
ADC1OV
Reserved
ADC1DAT1
23
22
21
20
19
18
17
16
ADC1DAT1
15
14
13
12
11
10
9
8
ADC0VALID
ADC0OV
Reserved
ADC0DAT1
7
6
5
4
3
2
1
0
ADC0DAT1
Bits
Description
[31]
ADC1VALID
ADC1 Valid Flag
0 = Data in ADC1DAT1[27:16] bits not valid.
1 = Data in ADC1DAT1[27:16] bits valid.
Note:
This bit is set to “1” when A/D conversion is completed and cleared by hardware
after the ADC_DAT1 register is read.
[30]
ADC1OV
ADC1 over Run Flag
0 = Data in ADC1DAT1[27:16] is recent conversion result.
1 = Data in ADC1DAT1[27:16] overwritten.
Note1:
If converted data in ADC1DAT1[27:16] has not been read before the new
conversion result is loaded to this register, OV is set to “1”.
Note2:
It is cleared by hardware after the ADC_DAT1 register is read.
[29:28]
Reserved
Reserved.
[27:16]
ADC1DAT1
ADC1 Conversion Result for FIFO1
This field contains conversion result of ADC.
[15]
ADC0VALID
ADC0 Valid Flag
0 = Data in ADC0DAT1[11:0] bits not valid.
1 = Data in ADC0DAT1[11:0] bits valid.
Note:
This bit is set to “1” when A/D conversion is completed and cleared by hardware
after the ADC_DAT1 register is read.
[14]
ADC0OV
ADC0Over Run Flag
0 = Data in ADC0DAT1[11:0] is recent conversion result.
1 = Data in ADC0DAT1[11:0]] overwritten.
Note1:
If converted data in ADC0DAT1[11:0] has not been read before the new
conversion result is loaded to this register, OV is set to “1”.
Note2:
It is cleared by hardware after the ADC_DAT1 register is read.
[13:12]
Reserved
Reserved.