Mini57
Apr. 06, 2017
Page 398 of 475
Rev.1.00
MINI5
7
S
E
RI
E
S
TECH
NIC
A
L R
E
F
E
RE
N
CE
MA
N
UA
L
RXDAT
(SLA+W=0x00)
(PTRG, STA, STO, AA)=(0, 0, 0, 1)
GCFUNC = 1
Clear protocol status register
ACKIF = 1
RXDAT
(Data)
(PTRG, STA, STO, AA)=(1, 0, 0, 1)
Writing 1 to ACKIF
...
RXDAT
(Data)
(PTRG, STA, STO, AA)=(1, 0, 0, 0)
Writing 1 to ACKIF
ACKIF = 1
ACKIF = 1
S
(PTRG, STA, STO, AA)=(1, 1, 0, 1)
Writing 1 to ACKIF
Write 1 to STORIF
...
...
Switch to not addressed mode
Own SLA will be recognized
Send START when bus free
S
(PTRG, STA, STO, AA)=(1, 1, 0, 0)
Writing 1 to ACKIF
Write 1 to STORIF
...
...
Switch to not addressed mode
Own SLA will not be recognized
Send START when bus free
...
Switch to not addressed mode
Address 0x0 will be recognized
(PTRG, STA, STO, AA)=(1, 0, 0, 0)
Writing 1 to ACKIF
Write 1 to STORIF
Switch to not addressed mode
Own SLA will not be recognized
Become I
2
C Master
Become I
2
C Master
Become I
2
C Master
Become I
2
C Master
Bus Free
Bus Free
...
(PTRG, STA, STO, AA)=(1, 0, 0, 1)
Writing 1 to ACKIF
Write 1 to STORIF
Switch to not addressed mode
Own SLA will be recognized
Become I
2
C Slave
Become I
2
C Slave
RXDAT
(SLA+W=0x00)
ARBLOIF = 1
Arbitraion Lost
Arbitraion Lost
Master to Slave
Master to Slave
Slave to Master
Slave to Master
STORIF = 1
Sr
Sr
...
Sr
(PTRG, STA, STO, AA)=(1, 0, 0, X)
Writing 1 to ACKIF
(Writing 1 to ARBLOIF)
(PTRG, STA, STO, AA)=(1, 0, 0, X)
Writing 1 to ACKIF
(Writing 1 to ARBLOIF)
S
ACK
NAK
ACK
NAK
P
STARIF=1
Figure 6.14-16 GC Mode with 7-bit Address
If I
2
C is still receiving data in GC mode but got a STOP or Repeat START, the STORIF
(UI2C_PROTSTS [9]) or STARIF (UI2C_PROTSTS [8]) will be set. User could follow the action
for NACKIF (UI2C_PROTSTS [10]) in Figure 6.14-16when got STORIF (UI2C_PROTSTS [9]) or
STARIF (UI2C_PROTSTS [8]) is set.
Note:
After slave gets interrupt flag of NACKIF (UI2C_PROTSTS [10]) and start/stop symbol
including STARIF (UI2C_PROTSTS [8]) and STORIF (UI2C_PROTSTS [9]), slave can switch to
not address mode and own SLA will not be recognized. If setting this interrupt flag, slave will not
receive any I
2
C signal or address from master. At this time, I
2
C controller should be reset by
setting FUNMODE (UI2C_CTL [2:0]) = 000B to leave this status.