Mini57
Apr. 06, 2017
Page 185 of 475
Rev.1.00
MINI5
7
S
E
RI
E
S
TECH
NIC
A
L R
E
F
E
RE
N
CE
MA
N
UA
L
Bits
Description
[3:0]
DBCLKSEL
De-bounce Sampling Cycle Selection
0000 = Sample interrupt input once per 1 clocks.
0001 = Sample interrupt input once per 2 clocks.
0010 = Sample interrupt input once per 4 clocks.
0011 = Sample interrupt input once per 8 clocks.
0100 = Sample interrupt input once per 16 clocks.
0101 = Sample interrupt input once per 32 clocks.
0110 = Sample interrupt input once per 64 clocks.
0111 = Sample interrupt input once per 128 clocks.
1000 = Sample interrupt input once per 256 clocks.
1001 = Sample interrupt input once per 2*256 clocks.
1010 = Sample interrupt input once per 4*256 clocks.
1011 = Sample interrupt input once per 8*256 clocks.
1100 = Sample interrupt input once per 16*256 clocks.
1101 = Sample interrupt input once per 32*256 clocks.
1110 = Sample interrupt input once per 64*256 clocks.
1111 = Sample interrupt input once per 128*256 clocks.