Mini57
Apr. 06, 2017
Page 220 of 475
Rev.1.00
MINI5
7
S
E
RI
E
S
TECH
NIC
A
L R
E
F
E
RE
N
CE
MA
N
UA
L
Bits
Description
[9:8]
CAPSEL0
CAP0 Input Source Selection
00 = CAP0 input is from port pin ECAP_P0.
01 = CAP0 input is from signal ACMP0_O (Analog comparator 0 output).
10 = CAP0 input is from signal ACMP1_O (Analog comparator 1 output).
11 = CAP0 input is from signal ADC_CPR (ADC compare output).
[7]
Reserved
Reserved.
[6]
IC2EN
Enable Port Pin IC2 Input to Input Capture Unit
0 = IC2 input to Input Capture Unit Disabled.
1 = IC2 input to Input Capture Unit Enabled.
[5]
IC1EN
Enable Port Pin IC1 Input to Input Capture Unit
0 = IC1 input to Input Capture Unit Disabled.
1 = IC1 input to Input Capture Unit Enabled.
[4]
IC0EN
Enable Port Pin IC0 Input to Input Capture Unit
0 = IC0 input to Input Capture Unit Disabled.
1 = IC0 input to Input Capture Unit Enabled.
[3]
CAPNFDIS
Disable Input Capture Noise Filter
0 = Noise filter of Input Capture Enabled.
1 = The noise filter of Input Capture Disabled.
[2]
Reserved
Reserved.
[1:0]
NFCLKS
Noise Filter Clock Pre-divided Selection
To determine the sampling frequency of the Noise Filter clock
00 = ECAP_CLK.
01 = ECAP_CLK / 2.
10 = ECAP_CLK / 4.
11 = ECAP_CLK / 16.