2.7.4
Printer web page
The
Printer
web page can be opened from the
Advanced Configuration
web
page (2.7.2) by clicking on
Printer
.
Select
Network – Port 9100
if the SafeCom Controller connects to the printer
via the network. On the obsolete SafeCom Controller 3 Port and 1 Port select
Parallel Port
if the printer is connected to the SafeCom Controller’s
PAR1
port.
Printer IP Address
must be correct if the SafeCom Controller is to control
copying on any attached MFP. For fixed IP addresses, use the printer's IP
address. For DCHP IP addresses, use the printer’s hostname.
Use auto-configuration
should normally be
YES to
allow the SafeCom
Controller to automatically determine the
Printer Manufacturer
and
Model
. Both of these are used to ensure correct operation of the SafeCom MFP
Cable.
SafeCom Go
should be
YES
if
Printer Manufacturer
is
Xerox
and the
MFP is EIP-enabled.
Copy Enabled
should be
YES
if a SafeCom MFP Cable is connected to control
copying. The process of enabling Copy Control is MFP dependent and covered in
more detail in 2.6.
Copy Idle Timeout
. When the SafeCom controller automatically logs-out the
user after the MFP is idle for a length of time. If
Idle timeout
is set to
0
there
is no timeout.