![NSD VARICAM VS-5F Series Specifications And Instruction Manual Download Page 88](http://html1.mh-extra.com/html/nsd/varicam-vs-5f-series/varicam-vs-5f-series_specifications-and-instruction-manual_1714384088.webp)
78
OPERATION
8. HOW TO USE APPLIED FUNCTIONS (PARAMETER)
8-13. Serial Communication Function
This function is applicable with all VS-5F Series.
VARICAM is equipped the serial communication connector, so following functions are available:
- Data can read and write by communicating with the host controller.
- Connectable with the touch panel
- Connectable with the external display unit (NDP)
- VARICAM can use the setting and editing software “VS-5F-EDW2”, so the data can be read, edited, written, and
printed by the personal computer.
For more details regarding the serial communication, please contact your NSD representative.
●
Parameter list (1/2)
No.
Name
Description
Setting range
Initial
value
Reference for
setting procedure
(Chapter No.)
89
Communication
setting
Designates this function when writing
data to VARICAM by communication.
Writing is available when selecting “1:
Setting enabled”.
- The setting values of all switch output
and parameter can be writable.
- This setting is invalid when changing
the mode from parameter setting
(PRM) to others.
0: Setting disabled
1: Setting enabled
0
8-1-1
8-1-2
86
Node number
Designates this function when “9
(VARIMONI)” is selected at the
parameter No. 85.
Designates the node number to
VARICAM.
0 to 15
1
8-1-1
8-1-3
85
Protocol
Selects the communication protocol.
0: NSD
1: MELSEC-A
(Bidirectional protocol)
2: MELSEC (MC protocol)
3: OMRON
8: NDP (external display unit)
9: VARIMONI
0
8-1-1
8-1-2
84
Device
selection
Designates this function when “2:
MELSEC (MC protocol)” is selected at
the parameter No. 85.
Selects the device of programmable
controller.
0: D (Data register)
1: R (File register)
0
8-1-1
8-1-2
CAUTION
When “2” or “3” is selected at the parameter No. 85 (Protocol), parameter No. 97 (Program No.
input format) is disabled and the selecting program No. is fixed to ”0”
Summary of Contents for VARICAM VS-5F Series
Page 2: ......
Page 22: ...12 SUMMARY 2 MODEL SELECTION WHEN ORDERING MEMO ...
Page 33: ...23 SPECIFICATION 4 OUTER DIMENSIONS VRE P028SAC Units mm ...
Page 50: ...40 INTRODUCTORY 6 WIRING and CONNECTION MEMO ...
Page 108: ...98 OPERATION 10 HOW TO USE APPLIED FUNCTIONS OPERATION MODE MEMO ...
Page 114: ...104 MAINTENANCE 12 TROUBLE SHOOTING MEMO ...
Page 121: ...111 APPENDIX APPENDIX 1 PASSWORD FUNCTION MEMO ...
Page 129: ......