No.
Name
Setting range
Applicable model
Initial
value
Setting
value
VS-5F VS-5FD VS-5FX
93
Timing pulse
0: 360 pulses
1: 180 pulses
2: 60 pulses
3: Motion detection switch
Display: 360
Display: 180
Display: 60
Display: Spd
○
○
○
0
92
Setting change
during operation
0: Change disable
1: Change enable
○
○
○
0
91
Latch pulse cycle
Edge timing
0: 0.352 ms
1: 17.58 ms
2: 35.16 ms
Level timing
3: 1.406 ms
4: 4.219 ms
5: 8.438 ms
6: 17.58 ms
7: 35.16 ms
8: 70.32 ms
9: 140.6 ms
Display: 0.35
Display: 17.6
Display: 35.2
Display: 1.41
Display: 4.22
Display: 8.44
Display: 17.6
Display: 35.2
Display: 70.3
Display: 141
○
○
0
90
Switch output
enabling range
VS-5F(-1)
VS-5FD(-1)
VS-5FX(-1)
: 0 to 24
: 0 to 24
: 0 to 40
○
○
○
0
89
Communication
setting
0: Setting disabled
1: Setting enabled
○
○
○
0
86
Node number
0 to 15
○
○
○
1
85
Protocol
0: NSD
1: MELSEC-A (Bidirectional protocol)
2: MELSEC (MC protocol)
3: OMRON
8: NDP (external display unit)
9: VARIMONI
○
○
○
0
Summary of Contents for VARICAM VS-5F Series
Page 2: ......
Page 22: ...12 SUMMARY 2 MODEL SELECTION WHEN ORDERING MEMO ...
Page 33: ...23 SPECIFICATION 4 OUTER DIMENSIONS VRE P028SAC Units mm ...
Page 50: ...40 INTRODUCTORY 6 WIRING and CONNECTION MEMO ...
Page 108: ...98 OPERATION 10 HOW TO USE APPLIED FUNCTIONS OPERATION MODE MEMO ...
Page 114: ...104 MAINTENANCE 12 TROUBLE SHOOTING MEMO ...
Page 121: ...111 APPENDIX APPENDIX 1 PASSWORD FUNCTION MEMO ...
Page 129: ......