69
OPERATION
8. HOW TO USE APPLIED FUNCTIONS (PARAMETER)
8-7. Hysteresis Function
This function is applicable with all VS-5F Series.
When the rotation direction of ABSOCODER’s shaft reverses, this function keeps the current position value before
reversing until the value exceeds the setting value.
This function is used when flicking the current position value even though machine is stopped.
If the switch output repeatedly turns ON or OFF, this function can stabilize the switch output.
This function sets by the parameter No. 40 (Hysteresis angle).
●
Parameter list
No.
Name
Description
Setting range
Initial
value
Reference for
setting procedure
(Chapter No.)
40
Hysteresis
angle
Designates a hysteresis angle when controlling
flickers of the current position value.
Setting unit is 0.5
°
.
0.0 to 10.0
°
0
8-1-1