61
OPERATION
8. HOW TO USE APPLIED FUNCTIONS (PARAMETER)
●
Switch output parameter (2/4)
No.
Name
Description and setting range
Applicable model
Reference
(Chapter No.)
VS-5F VS-5FD VS-5FX
97
Program No.
input format
Selects the input format of the program No. to be operated.
0: By panel key input
1: By external connector input
2: By serial communication
○
○
8-2
96
Protected switch
Selects whether or not the protected switch function is to be
used.
The switch Nos. 1 to 10 is set as the protected switch when
selecting “1:VALID”.
0: INVALID 1: VALID
○
○
○
8-3
95
Protected switch
cancel
Uses this function when selecting the protected switch by the
parameter No. 96 (protected switch).
The protected switch setting value can be changed by
selecting “1:cancel”.
0: Do not cancel 1: Cancel
○
○
○
8-3
94
Output status in
SET mode
Selects the switch output status when changing the switch
setting (SET) mode or parameter setting (PRM) mode from
operation (RUN) mode.
0: Output OFF 1: Output HOLD
○
○
○
8-6
93
Timing pulse
VS-5F(-1)
VS-5FD(-1)
VS-5FX(-1)
: Switch output connector A5-pin
: Switch output connector A5-pin and
BCD output connector B11-pin
: BCD output connector B11-pin
○
○
○
8-4
8-5
Changes the timing pulse and motion detection switch
function.
Timing pulse function is selecting number of output pulses per
revolution.
0: 360 pulses
1: 180 pulses
2: 60 pulses
3: Motion detection switch
Display: 360
Display: 180
Display: 60
Display: Spd
92
Setting change
during operation
Designates the function when fine-adjusting the switch output
during the operation.
0: Change disable 1: Change enable
○
○
○
10-3
90
Switch output
enabling range
Switch output connector B4-pin
Designates controlling numbers of switch output by the
switch output enabling signal.
○
○
○
8-8
VS-5F(-1)
VS-5FD(-1)
VS-5FX(-1)
0
: 0 to 24
: 0 to 24
: 0 to 40
75
Motion detection
switch OFF
Designates a value that the motion detection switch output
turns OFF.
“3: Motion detection switch” needs to be selected at the
parameter No. 93 (timing pulse).
Setting range: 0 to 6000 r/min
0 r/min
○
○
○
8-5
74
Motion detection
switch ON
Designates a value that the motion detection switch output
turns ON.
“3: Motion detection switch” needs to be selected at the
parameter No. 93 (timing pulse).
Setting range: 0 to 6000 r/min
0 r/min
○
○
○
8-5
40
Hysteresis angle
Designates a hysteresis angle when controlling flickers of the
current position value.
Setting unit is 0.5
°
.
Setting range: 0.0 to 10.0
°
0.0
°
○
○
○
8-7
Summary of Contents for VARICAM VS-5F Series
Page 2: ......
Page 22: ...12 SUMMARY 2 MODEL SELECTION WHEN ORDERING MEMO ...
Page 33: ...23 SPECIFICATION 4 OUTER DIMENSIONS VRE P028SAC Units mm ...
Page 50: ...40 INTRODUCTORY 6 WIRING and CONNECTION MEMO ...
Page 108: ...98 OPERATION 10 HOW TO USE APPLIED FUNCTIONS OPERATION MODE MEMO ...
Page 114: ...104 MAINTENANCE 12 TROUBLE SHOOTING MEMO ...
Page 121: ...111 APPENDIX APPENDIX 1 PASSWORD FUNCTION MEMO ...
Page 129: ......