![Novation Supernova II User Manual Download Page 96](http://html1.mh-extra.com/html/novation/supernova-ii/supernova-ii_user-manual_1711565096.webp)
ENVELOPES SECTION
The higher parameter is “Env 3 A-D repeat”. In this case with a value of 022.
This parameter controls the number of times the Attack/Decay cycles of the selected envelope repeat before entering the sustain
phase of the envelope. The operation of this parameter is identical to Env 1 A-D repeat parameter on page 3 but applies to
Envelope 2.
The range of this parameter is Off, 1 to 126 & Inf (Infinite). This parameter is memorised with a Program.
Page 10 looks like so:
The higher parameter is “Env 3 sustain rate”. In this case with a value of +00.
This parameter is used to control the slope of the “Sustain” phase of the envelope. Use the higher Data knob to adjust this parame-
ter. The operation of this parameter is identical to Env 1 sustain rate parameter on page 4 but applies to Envelope 2. The range of
this parameter is -64 to +63. This parameter is memorised with a Program.
The lower parameter is “Env 3 sustain time”. In this case with a value of 000.
This parameter controls the length of time the “Sustain” phase of the envelope lasts. Use the lower Data knob to adjust this para-
meter. The operation of this parameter is identical to Env 1 sustain time parameter on page 4 but applies to Envelope 2. The
range of this parameter is 000 to 126 & Key. This parameter is memorised with a Program.
ENV 2 - Button
ENV 3 - Button
These buttons select which Envelope this set of knobs & buttons is going to adjust.
Multi Trigger - Button ( ENV 2/3 )
Multi Trigger - Button ( ENV 1 )
These buttons determine how the Envelopes 1, 2 & 3 trigger. When a Multi trigger is activated ( the button is lit ) the triggering for
the envelopes is in “Multi” mode & any new note received will retrigger the envelope. When Multi trigger is disabled ( the button is
unlit ) the triggering for the envelopes is in “Single” mode triggering & there must be a gap in-between received notes for the enve-
lope to retrigger. ( Legato notes will not retrigger the envelope ) The range of this parameter is On ( Multi ) or Off ( Single ). This
parameter is memorised with a Program.
Delay - Knob ( ENV 2/3 )
This parameter introduces a Delay time before the selected Envelope starts when a note is struck on the master keyboard. Turning
this knob fully anticlockwise sets no delay. i.e. The selected Envelope will start immediately when a note is struck on the master
keyboard. turning this knob clockwise will introduce an increasing amount delay before selected Envelope starts after a note has
been struck on the master keyboard. The range of this parameter is Off, 1 to 127. This parameter is memorised with a Program.
Attack - Slider ( All Envelopes )
This slider sets how quickly the Envelope rises to its maximum level when a note is struck. Set to 000, this is instantaneous
increasing exponentially to 20 seconds when set to 127. The range of this parameter is 000 to 127. This parameter is memorised
with a Program.
Decay - Slider ( All Envelopes )
This slider sets how quickly the Envelope drops off to the Sustain level once the Maximum level has been reached by the Attack
time. Set to 000, this is instantaneous increasing exponentially to 20 seconds when set to 127. The range of this parameter is 000
to 127. This parameter is memorised with a Program.
Sustain - Slider ( All Envelopes )
This slider sets the level at which the Envelope remains at after the Decay phase until the note is released. Set to 000 the
Envelope will decay all the way to zero without being interrupted. As the slider is moved higher, the level at which the Decay is
Env 3 sust rate +OO
Env 3 sust time C3
96
Summary of Contents for Supernova II