056341 Rev. AA
NAVIGAT X Mk 2
Page 8-16
8: Gyroshpere Installation and Service
15) Inject the mercury and insulating fluid
into the empty phial. Make sure no
traces of mercury remain in the syringe.
16) Carefully lift the gyrosphere out of the
container and pour the remaining sup-
porting fluid from the recess into the
plastic bowl.
17) Place the gyrosphere back into the lower
section of the gyrosphere container.
18) If there is are any mercury left in the
plastic bowl, collect it with the syringe
and inject it into the phial.
19) Close and seal the phial and put it back
into the protective capsule.
20) Dispose of the supporting fluid from the
plastic bowl.
Caution
Used mercury and insulating fluid may not be reused.
When re-installing or replacing a gyrosphere, always use fresh mercury and in-
sulating fluid. Return the capsule with used mercury and insulating fluid to
Sperry Marine for recycling.
21) Carefully lift the gyrosphere out of the
gyrosphere container and place it onto
the plastic bowl.
22) Dispose of the remaining supporting
fluid from the lower section of the gyro-
sphere container.
Summary of Contents for Sperry Marine NAVIGAT X MK 2
Page 8: ...056341 Rev AA NAVIGAT X Mk 2 vi ...
Page 30: ...056341 Rev AA NAVIGAT X Mk 2 Page 2 18 2 Operation ...
Page 52: ...056341 Rev AA NAVIGAT X Mk 2 Page 5 8 5 Installation ...
Page 66: ...056341 Rev AA NAVIGAT X Mk 2 Page 6 14 6 System Configuration ...
Page 92: ...056341 Rev AA NAVIGAT X Mk 2 Page A 2 App A Setup Tables ...
Page 94: ......
Page 96: ......
Page 98: ......
Page 100: ...056341 Rev AA NAVIGAT X Mk 2 Page B 2 App B Drawings ...
Page 101: ......
Page 102: ......
Page 103: ......
Page 104: ......
Page 105: ......
Page 106: ......
Page 107: ......
Page 108: ......
Page 109: ... ...
Page 110: ......
Page 111: ......