NAVIGAT X Mk 2
056341 Rev. AA
6: System Configuration
Page 6-9
6.1.3.2
Analog ROT Outp.
6.1.3.3
Protocol Type
6.1.3.4
System Type
Sc. Factor
Function:
Sets the scale factor for the analogue Rate of Turn output
Setting:
0.1 – 999.9 mV/°
Zero Offset
Function:
Sets the zero-point offset for the analogue Rate of Turn output
Settings:
-999 – +999 mV
Function:
Selects the conformance level for NMEA outputs
Settings: IEC 61162-1
NMEA outputs conform strictly to IEC 61162-1. Proprietary output
sentences start with $PPLA...
NMEA 0183
NMEA outputs use the older form of the proprietary nav. status
data sentence, $PPNSD.
System
Function:
Sets the system type
Settings: G
Standalone Gyro or Backup Gyro in systems without magnetic
heading input
G/M
Standalone Gyro or Backup Gyro in systems with magnetic heading
input