056341 Rev. AA
NAVIGAT X Mk 2
Page 8-12
8: Gyroshpere Installation and Service
8.4 Gyrosphere Maintenance Procedures
8.4.1
Removing the gyrosphere container from the compass housing
Parts required
–
a 5mm Allen key
–
a No. 2 Philips-head screwdriver
Procedure
1)
Make sure the compass' main and backup power supplies are switched off
and safeguarded against accidental switching-on.
2)
Unscrew the 5 mm Allen-head screws of
the compass housing door and take off
the door from the housing
3)
Disconnect the grounding strap be-
tween door and housing. Place the door
aside. If the door is put next to the hous-
ing, the keypad's ribbon cable may be
left connected to the main PCB.
4)
Unplug the gyrosphere supply and
phase bridge connector from its socket
on the gyrosphere container.
5)
Gently turn the bellows, until the largest
of the three coupling seats in the bayo-
net collar points towards the front of the
housing. the seat is marked by a green
dot on the collar.
Summary of Contents for Sperry Marine NAVIGAT X MK 2
Page 8: ...056341 Rev AA NAVIGAT X Mk 2 vi ...
Page 30: ...056341 Rev AA NAVIGAT X Mk 2 Page 2 18 2 Operation ...
Page 52: ...056341 Rev AA NAVIGAT X Mk 2 Page 5 8 5 Installation ...
Page 66: ...056341 Rev AA NAVIGAT X Mk 2 Page 6 14 6 System Configuration ...
Page 92: ...056341 Rev AA NAVIGAT X Mk 2 Page A 2 App A Setup Tables ...
Page 94: ......
Page 96: ......
Page 98: ......
Page 100: ...056341 Rev AA NAVIGAT X Mk 2 Page B 2 App B Drawings ...
Page 101: ......
Page 102: ......
Page 103: ......
Page 104: ......
Page 105: ......
Page 106: ......
Page 107: ......
Page 108: ......
Page 109: ... ...
Page 110: ......
Page 111: ......