RAID operations
Standard 1.06
178
CallPilot
Result:
The system should display both SCSI channels, each
having one drive. SCSI IDs should be 0 for each channel. All disk
drives should be in READY state.
Note:
Do not use the Load command on the Configure menu. This
command is not for RAID operations.
12
Create the first logical drive by selecting Channel-1 ID 0 (A01-01),
and pressing the Spacebar. The display will change to ONLIN A01-
01. Select Channel-2 ID-0 (A01-02) and again press the Spacebar.
Result:
After selection, the drives will blink.
13
Press Enter to End the Array.
Result:
The blinking stops.
14
Press F10 to configure the logical drive.
15
Press the space bar to select Configuration Array.
Result:
Span-1 appears in the box opened for the A01 logical drive.
16
Press F10 to configure the logical drives.Then press the space bar
to select configuration array.
Result:
Span-1 appears in the box opened for the A01 logical drive.
Configure the logical drives by pressing F10 again.
Result:
The system prompts you for each of the logical drives to
consecutively select:
RAID 1;
Size:
accept the size displayed
Advanced Menu
Accept
SPAN
= NO
Change the last value to NOSPAN if required.
17
Highlight Accept and press Enter twice to accept these new values.
Result:
The system prompts you to save the configuration.
18
Highlight YES and press Enter.
19
Press ESC twice to exit the submenus.
Summary of Contents for 703t
Page 6: ...Standard 1 06 6 CallPilot...
Page 8: ...8 CallPilot Publication history Standard 1 06...
Page 12: ...Task List Standard 1 06 12 CallPilot...
Page 16: ...Contents Standard 1 06 16 CallPilot...
Page 64: ...Using Windows online diagnostic tools Standard 1 06 64 CallPilot...
Page 76: ...Using serial port diagnostic tools Standard 1 06 76 CallPilot...
Page 118: ...Using CallPilot system utilities Standard 1 06 118 CallPilot Figure 13 Legend Help tab...
Page 144: ...Replacing basic chassis components Standard 1 06 144 CallPilot...
Page 170: ...Replacing media drives Standard 1 06 170 CallPilot...
Page 188: ...RAID operations Standard 1 06 188 CallPilot...
Page 196: ...Replacing or adding voice processing boards Standard 1 06 196 CallPilot...
Page 247: ......