Chapter 3 Configuring the management IP interface
51
Installing the Contivity 1700
Troubleshooting
If you cannot connect to the Contivity 1700 using your browser, check the
following items:
•
Make sure that you entered the correct IP address in the browser window.
•
Type a known URL in the browser window to make sure that your network
connection is good.
•
Check that the management IP address that you configured is on the same
subnet as the physical LAN attached to the gateway.
•
Make sure that your PC is running a supported browser, either Internet
Explorer Version 5.5 or later, or Netscape Navigator
*
4.79 or 6.2.
•
Check the physical connections on the Contivity 1700, especially the LAN
cable and the power cord.
If you still cannot connect to the Contivity 1700 using a browser, connect a
terminal or PC to the gateway with the serial cable and check the management IP
address listed in the serial menu (see
“Configuring the management IP address”
on page 45
). Reconfigure the management IP address if necessary.
If you cannot resolve the problem, contact the Nortel Networks Technical
Solutions Center closest to you (see
“How to get help” on page 18
).
Summary of Contents for 1700
Page 6: ...6 314711 D Rev 00 ...
Page 10: ...10 Contents 314711 D Rev 00 ...
Page 14: ...14 Tables 314711 D Rev 00 ...
Page 28: ...28 Chapter 1 Installing the Contivity 1700 chassis 314711 D Rev 00 ...
Page 42: ...42 Chapter 2 Cabling the gateway and turning the power on 314711 D Rev 00 ...
Page 50: ...50 Chapter 3 Configuring the management IP interface 314711 D Rev 00 Figure 16 Welcome screen ...
Page 52: ...52 Chapter 3 Configuring the management IP interface 314711 D Rev 00 ...
Page 88: ...88 Appendix A Technical specifications 314711 D Rev 00 ...
Page 94: ...94 Index 314711 D Rev 00 ...