Mode Table Notes:
• [1] Setting the Console in Away Mode clears all supervisory events for
emergency sensors only. Supervisory timers for Smoke detectors, CO
detectors, and activity monitor sensors are not affected; switching to Home
or Away Mode constitutes activity.
• [2] Supervisory events are reported by automatic status reports regardless
of the global
REPORT SUPERVISORY EVENTS
setting. Also, AC power
loss events are reported by automatic status reports regardless of the global
REPORT AC FAIL
setting. Both settings are on the Reporting Options tab.
• [3] If
ENABLE HOME MODE ONLY
is selected for
TEMPERATURE LIMIT
SETTIN
G
S
on the Console tab, temperature alarms will not occur in this
mode. Select
ENABLE
to allow temperature alarms in this mode.
• [4] Either
ENABLE
or
ENABLE HOME MODE ONLY
needs to be selected
on the Console tab for
TEMPERATURE LIMIT SETTIN
G
S
to allow
temperature alarms.
• [5] Console supervisory faults are always reported, but not annunciated in
Away Mode and Night Mode.
• [6] To start a two-way audio session after a report is triggered by an
emergency alarm sensor, two-way audio must be globally enabled in
TWO-WAY AUDIO MODE
on the Reporting Options tab and enabled for the
sensor’s zone with the
TWO-WAY AUDIO
check box on the Sensors tab.
• [7] For activity sensors, two-way audio is enabled globally in
TWO-WAY
AUDIO MODE
on the Reporting Options tab regardless of the activity
sensor’s zone setting with the
TWO-WAY AUDIO
check box on the Sensors
tab.
• [8] To enable Console/sensor zone low battery and sensor zone
supervision annunciations,
ANNUNCIATE TROUBLE INDICATION
must
be selected on the Console tab.
• [9] To announce telephone line and AC power status,
ANNUNCIATE
PHONE-LINE/AC STATUS
must be selected on the Console tab.
• [10] The Console will only announce Home Mode when manually switched
from Away Mode using the
HOME
button.
• [11] To report missed reminder messages, the global
REPORT MISSED
REMINDER
option must be selected on the Reminder Messages tab and
the reminder message slot must have the
SEND REPORT
option selected.
18. Appendix B - Mode Table
CONSOLE OPERATIN
G
MODE
HOME MODE
AWAY MODE
(Overrides Night Mode)
NI
G
HT MODE
Repor
ts to Central Station
V
oice Announcement
Star
ts T
w
o-wa
y
A
udio
Repor
ts to Central Station
V
oice Announcement
Star
ts T
w
o-wa
y
A
udio
Repor
ts to Central Station
V
oice Announcement
Star
ts T
w
o-wa
y
A
udio
SYSTEM EVENT
Fire & CO Alarms
✓
Yes
✓
Yes
~
If Enabled
[6]
✓
Yes
✓
Yes
~
If Enabled
[6]
✓
Yes
✓
Yes
~
If Enabled
[6]
Fire & CO Supervisory
Timeout
[2]
✓
Yes
~
If Enabled
[8]
N/A
✓
Yes
✗
No
N/A
✓
Yes
✗
No
N/A
Fire & CO Sensor Low
Battery
[2]
✓
Yes
~
If Enabled
[8]
N/A
✓
Yes
✗
No
N/A
✓
Yes
✗
No
N/A
Console (
HELP
button) Alarm
✓
Yes
✓
Yes
~
If Enabled
✓
Yes
✓
Yes
~
If Enabled
✓
Yes
✓
Yes
~
If Enabled
Emergency Sensor Alarm
✓
Yes
✓
Yes
~
If Enabled
[6]
✓
Yes
✓
Yes
~
If Enabled
[6]
✓
Yes
✓
Yes
~
If Enabled
[6]
Emergency Sensor
Supervisory Timeout
[2]
~
If Enabled
~
If Enabled
[8]
N/A
✗
No
[1]
✗
No
[1]
N/A
~
If Enabled
✗
No
✗
No
Emergency Sensor Low
Battery
[2]
✓
Yes
~
If Enabled
[8]
N/A
✓
Yes
✗
No
[1]
N/A
✓
Yes
✗
No
N/A
Console Trouble
[2] & [5]
✓
Yes
~
If Enabled
[8] & [9]
N/A
✓
Yes
✗
No
N/A
✓
Yes
✗
No
N/A
Communication Status
(telephone/cell)
✗
No
✓
Yes
N/A
✗
No
✓
Yes
N/A
✗
No
✗
No
N/A
Module Status
N/A
✓
Yes
N/A
N/A
✗
No
N/A
N/A
✗
No
N/A
Activity Monitor
✓
Yes
✓
Yes
~
If Enabled
[7]
✗
No
✗
No
✗
No
✓
Yes
✓
Yes
~
If Enabled
[7]
Temperature Alarms
~
If Enabled
[4]
~
If Enabled
[4]
~
If Enabled
[4]
~
If Enabled
[3]
~
If Enabled
[3]
~
If Enabled
[3]
~
If Enabled
[3]
~
If Enabled
[3]
~
If Enabled
[3]
Missed Reminder Messages
✓
Yes
[11]
✓
Yes
~
If Enabled
✗
No
✗
No
✗
No
✓
Yes
[11]
✓
Yes
~
If Enabled
Entering Mode
✓
Yes
From Away
Mode Only
[10]
N/A
✓
Yes
✓
Yes
N/A
From Away
Mode Only
From Away
Mode Only
N/A