28
12.3 Sending and Receiving Console Data
Once the Console is connected to the RA4200 software, data can be
exchanged in either direction.
Console Time and Date
The Console’s clock and calendar will maintain the current time & date.
✲
IMPORTANT! THE CONSOLE’S TIME AND DATE MUST BE SET PRIOR TO
USE TO SUPPORT THE EVENT LO
GG
IN
G
AND REMINDER MESSA
G
E
FEATURES.
✓
NOTE: If the Console is using IP reporting, the Console’s data and time
are automatically set by the cellular network.
If the Console’s clock or calendar needs setting or changing, use these
steps.
1.
Connect to the Console. The green
CONNECTED
indicator will
display at the bottom of the RA4200 window.
2.
Press
CONSOLE TIME
. The SetTime window will display.
3.
To check a Console’s clock and calendar, press
G
ET TIME
. The
current settings will be displayed in the SetTime window.
— OR —
4.
Enter the new time and date. If daylight saving time is enabled, verify
the start and stop dates. Press
SET TIME
to update the Console’s
date and time.
5.
Press
DONE
to close the SetTime window.
First Time Programming for New Consoles
When a Console is new or un-programmed it will announce:
0
“Console not ready... please confi gure before use”
The Console must be programmed with an account number, a Central
Station phone number and a corresponding PSTN or IP reporting format.
If one or more of these required parameters is missing the Console will
not operate.
Use the following steps when programming a new Console:
1.
Open the Account Template created for the specifi c User and Console
installation.
2.
Connect to the Console. The green
CONNECTED
indicator will
display at the bottom of the RA4200 window.
3.
Press
CONSOLE TIME
. The SetTime window will display. If not
correct, enter the correct time and date. If daylight saving time is
enabled, verify the start and stop dates. Press
SET TIME
to update
the Console’s date and time. Press
DONE
.
4.
Press
SET CONSOLE
. The template will be sent to the Console.
5.
Press
DISCONNECT
to disconnect from the Console. The red
NOT
CONNECTED
indicator will display at the bottom of the RA4200
window.
Existing Console Programming
Connecting to a Console with existing programming can be managed
two ways:
• Method 1: Make the changes to an Account Template off-line fi rst, before
connecting to the Console, then connect to the Console and send it the
template.
• Method 2: Open an Account Template, connect to the Console, then retrieve
the data from the Console into the template.
The fi rst method is preferred when all programming for a Console has
been made (and is being stored) by the RA4200 software. This method
will keep all the PERS provider’s Consoles synchronized with the RA4200
Account Template fi les.
The second method is useful if programming changes have been made
to a Console through remote touch-tone telephone programming. Those
changes can be retrieved into an Account Template, updating the
template. Be sure to save the template after updating it.
Use the following steps when programming an existing Console:
1.
Open the Account Template created for the specifi c User and Console
installation. (When using Method 1, make any changes required.)
2.
Connect to the Console. The green
CONNECTED
indicator will
display at the bottom of the RA4200 window.
3.
Method 1 - Press
SET CONSOLE
. The template will be sent to the
Console.
— OR —
4.
Method 2 - Press
G
ET CONSOLE
. The Console’s data will be sent to
the template. Press
SAVE
and select an Account Template fi le name.
✓
NOTE: The data in the open template will be overwritten with the data
from the Console.
5.
Press
DISCONNECT
to disconnect from the Console. The red
NOT
CONNECTED
indicator will display at the bottom of the RA4200
window.