30
13. Sensor Learn / Test Mode
In Learn / Test Mode the Console can learn new sensors, test sensors,
and erase all sensors.
✓
NOTE: While in Learn / Test Mode, all normal operations of PERS-4200
Console are suspended. No alarms or reports are made in this mode.
To exit this mode, press and release the
CANCEL
button. The Console
will exit Learn / Test Mode automatically after three minutes of no activity
(including RF activity from a learned sensor, which will extend Learn / Test
Mode for an additional 3 minutes).
13.1 Learning a Single Sensor
The Console can “learn” up to 16 sensors total. Use the following steps to
locally learn a single sensor into the Console:
1.
Pressing and hold the
CANCEL
button for fi ve seconds. The Console
will announce:
0
“Ready to learn sensor... Zone [number]”
2.
Activate the sensor to learn. The Console will announce:
0
“[Fire / Activity / Emergency / Carbon Monoxide] sensor learned”
3.
The Console will exit Learn/Test Mode after learning one sensor. To
exit without learning a sensor, press the
CANCEL
button.
13.2 Learning Multiple Sensors
The Console can “learn” up to 16 sensors. Use the following steps to
locally learn sensors into the Console:
1.
Press and release the
TEST
button (located recessed on the bottom
of the Console). The Console will announce:
0
“Test Mode, fi rmware version [number]...
hardware version [number]”
2.
Press and release the
TEST
button again. The Console will announce:
0
“Ready to learn sensor... Zone [number]”
3.
Activate the sensor to learn. The Console will announce:
0
“[Fire, Activity, Emergency, or Carbon Monoxide] sensor learned”.
4.
The Console will announce the next available zone number:
0
“Ready to learn sensor... Zone [number]”
To advance to the next available zone without learning a sensor, press
the
TEST
button. Zones already programmed with a sensor are skipped.
5.
Repeat Step 3 for each additional sensor (up to 16 total). When all
zone locations are full, the Console will announce:
0
“Zones full”
After Zone 16 has been skipped or learned, if there are any available
zones remaining, the learn sequence will advance to the fi rst available
skipped zone and allow learning another sensor. The learn sequence
will cycle through any available/skipped zones until either all zones are
programmed, or Learn / Test Mode is exited.
✓
NOTE: To exit Learn / Test Mode at any time, press the CANCEL button.
Learning Multiple Sensors
TE
S
T
B
UTTON
B
OTTOM OF PE
RS
-4
2
00 CON
S
OLE
P
R
E
SS
TE
S
T
B
UTTON, CON
S
OLE WILL
ANNOUNCE VE
RS
ION
P
R
E
SS
TE
S
T
B
UTTON A
G
AIN
CON
S
OLE WILL ANNOUNCE
R
EADY TO
LEA
R
N
S
EN
S
O
R
AND ZONE NUM
B
E
R
ACTIVATE
S
EN
S
O
R
CON
S
OLE WILL ANNOUNCE
S
EN
S
O
R
LEA
R
NED
R
EPEAT FO
R
ADDITIONAL
S
EN
S
O
RS
, O
R
P
R
E
SS
CANCEL TO EXIT
➀
➁
➂
➃
➄
➅
Learning a Single Sensor
CANCEL
B
UTTON
PE
RS
-4
2
00 CON
S
OLE
P
R
E
SS
AND HOLD THE CANCEL
B
UTTON
FO
R
FIVE
S
ECOND
S
CON
S
OLE WILL ANNOUNCE
R
EADY TO
LEA
R
N
S
EN
S
O
R
AND ZONE NUM
B
E
R
ACTIVATE
S
EN
S
O
R
CON
S
OLE WILL ANNOUNCE
S
EN
S
O
R
LEA
R
NED AND EXIT LEA
R
N MODE
➀
➁
➂
➃