Installation
3-6
Part 1126187_05
E
2021
Nordson Corporation
Step 2: Setting up the Air Kit and Applicator
NOTE:
Make sure the main air supply is switched Off.
1. Unpack the Pneumatic kit. You only need the Pneumatic assembly itself.
You will not need anything else in the Pneumatic kit bag.
2. Do the following to continue:
S
With the supplied air hose, connect the Air Output Port (3) to the Air
Supply Inlet (4).
S
Verify the Air Restrictor (5) is set to level 4. To change the setting,
lightly pull the restrictor knob out, then twist it to indicate
4
. When
done, push the knob back in.
S
Using a small flat-head screwdriver, remove the solenoid
connector(6).
3. Connect the air kit main air supply input (1) to your primary air supply.
B
A
1
3
4
2
5
6
Figure 3‐2 Air connections (A: Pneumatic kit/B: Applicator assembly)
1. Main air supply input
2. Air cap
3. Air output port
4. Air supply inlet
5. Air Restrictor
6. Solenoid Connector
4. Switch the air supply On.
5. Proceed to
Step 3, Connecting the Controller and Air Cables
.
NOTES:
S
The air supply must be clean, dry, regulated, and unlubricated
compressed air. Make sure the air connections are secure and leak
free.
S
The thread on the Air Kit connector is R ¼. You may need an adaptor
for your application.
Summary of Contents for Vulcan Jet
Page 26: ...Description 2 8 Part 1126187_05 E 2021 Nordson Corporation This page intentionally left blank...
Page 162: ...Parts 9 4 Part 1126187_05 E 2021 Nordson Corporation Figure 9 2 Vulcan Jet applicator parts...
Page 163: ...Parts 9 5 Part 1126187_05 E 2021 Nordson Corporation Figure 9 3 Vulcan Jet applicator parts...
Page 171: ......
Page 172: ......